Produção in vitro de biofilme em canetas odontológicas e eficiência de diferentes tratamentos na sua remoção
dc.contributor.advisor | Simonetti, Amauri Braga | pt_BR |
dc.contributor.author | Freitas, Valdionir da Rosa | pt_BR |
dc.date.accessioned | 2011-03-10T05:59:28Z | pt_BR |
dc.date.issued | 2010 | pt_BR |
dc.identifier.uri | http://hdl.handle.net/10183/27995 | pt_BR |
dc.description.abstract | Em consultórios odontológicos são utilizadas canetas rotatórias que durante seu uso entram em contato com a microbiota oral, podendo trazer conseqüências para o próprio paciente ou para outros que utilizarem o mesmo equipamento, se não houver um tratamento apropriado para sua reutilização. Para avaliar a eficiência de diferentes tratamentos utilizados rotineiramente na limpeza e desinfecção de equipamentos odontológicos, este trabalho descreve a produção de biofime in vitro em superfície de canetas odontológicas e a eficiência dos biocidas glutaraldeído, ácido peracético e álcool 70%, do detergente enzimático e da lavagem ultra-sônica para remoção do biofilme induzido, utilizando amostras de Pseudomonas aeruginosa e Staphylococcus aureus. Para a padronização dos métodos, além de curvas de crescimento de ambos os micro-organismos, foram realizados testes de adesão em cupons obtidos pelo corte das canetas. Foram testados diferentes tempos de incubação para a produção do biofilme, cujo valor máximo foi obtido em 14 dias. A avaliação da formação de biofilme foi realizada pelo método de contagem de bactérias viáveis (CBV), por microscopia eletrônica de varredura (MEV) e pelo método Cristal Violeta. A eficiência dos tratamentos na remoção do biofilme foi determinada pela diferença entre o número de células aderidas aos cupons submetidos ao tratamento e os cupons não submetidos. Maior remoção foi observada nos cupons tratados com ácido peracético, glutaraldeído e álcool 70% comparados aqueles tratados com detergente enzimático, lavagem ultra-sônica e solução salina. Os três primeiros tiveram eficiências similares, demonstradas pelos métodos CBV e MEV. O efeito dos tratamentos em S.aureus foi semelhante ao observado em P. aeruginosa, exceto a lavagem ultra-sônica que em S.aureus demonstrou melhor desempenho. Os tratamentos utilizados neste trabalho reduziram o biofilme em cupons de canetas odontológicas, mas não o removeram completamente, comprometendo a biossegurança na reutilização das canetas. | pt_BR |
dc.description.abstract | Rotating pens during its use in dental offices come into contact with the oral microbiota and may bring consequences to the patient or to others who use the same equipment, if there is not a clean suitable for reuse. To evaluate the efficiency of different treatments utilized routinely for cleaning dental equipments, this study describes the in vitro biofilm production on surfaces of dental pens and the efficiency of the biocides glutaraldehyde, peracetic acid, alcohol 70%, detergent enzyme and ultrasound rinsing for biofilm removal, using Pseudomonas aeruginosa and Staphylococcus aureus strains. For the standardization of methods, and growth curves of both microorganisms, adhesion tests were performed on coupons obtained by cutting the pens. We tested different incubation times for the production of biofilm, whose maximum value was obtained in 14 days. Evaluation of biofilm formation was performed by the method of counting viable bacteria (CBV) and scanning electron microscopy (SEM) and Crystal Violet method.The efficiency of treatments on biofilm removal was determined by the difference between the number of cells attached to coupons submitted and not submitted to treatment. Higher removal was observed on the coupons treated with peracetic acid, glutaraldehyde and 70% alcohol than in those treated with enzyme detergent, ultrasonic washing and saline. The first three had similar efficiencies, as demonstrated by CBV and SEM. The effect of treatment on S. aureus was similar to that observed in P. aeruginosa, except for ultrasonic washing in S. aureus that showed better performance. Therefore, the treatments used in this work reduced but not completely removed the biofilm in dental coupons pens, which can compromise the biological safety when they are reused. | en |
dc.format.mimetype | application/pdf | pt_BR |
dc.language.iso | por | pt_BR |
dc.rights | Open Access | en |
dc.subject | Biofilm | en |
dc.subject | Biofilmes | pt_BR |
dc.subject | Pseudomonas aeruginosa | pt_BR |
dc.subject | Pseudomonas sp. | en |
dc.subject | Staphylococcus sp. | en |
dc.subject | Staphylococcus aureus | pt_BR |
dc.subject | Praguicidas | pt_BR |
dc.subject | Biocide | en |
dc.subject | Instrumentos odontológicos | pt_BR |
dc.subject | Dental pen | en |
dc.subject | Biocidas | pt_BR |
dc.title | Produção in vitro de biofilme em canetas odontológicas e eficiência de diferentes tratamentos na sua remoção | pt_BR |
dc.title.alternative | In vitro production of biofilm in dental pens and efficiency of different treatments in removal | en |
dc.type | Dissertação | pt_BR |
dc.identifier.nrb | 000768127 | pt_BR |
dc.degree.grantor | Universidade Federal do Rio Grande do Sul | pt_BR |
dc.degree.department | Instituto de Ciências Básicas da Saúde | pt_BR |
dc.degree.program | Programa de Pós-Graduação em Microbiologia Agrícola e do Ambiente | pt_BR |
dc.degree.local | Porto Alegre, BR-RS | pt_BR |
dc.degree.date | 2010 | pt_BR |
dc.degree.level | mestrado | pt_BR |
Este item está licenciado na Creative Commons License
-
Ciências Agrárias (3295)