Mostrar registro simples

dc.contributor.authorMacedo, Carlos Alberto de Souzapt_BR
dc.contributor.authorScheidt, Rodrigo Benedetpt_BR
dc.contributor.authorPalma, Humberto Moreirapt_BR
dc.contributor.authorRosito, Ricardopt_BR
dc.contributor.authorWeissheimer Junior, Walmorpt_BR
dc.contributor.authorGalia, Carlos Robertopt_BR
dc.date.accessioned2012-06-14T01:34:36Zpt_BR
dc.date.issued2008pt_BR
dc.identifier.issn1413-7852pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/49666pt_BR
dc.description.abstractUma coorte de 48 pacientes (54 quadris) submetidos a artroplastia total primária de quadril não-cimentada com prótese de Spotorno®. O objetivo do estudo foi avaliar o desfecho clínico-radiológico da prótese de Spotorno®,em um período de 20 anos (1985 a 2005), com seguimento médio de 17,5 anos (8-20anos). Na avaliação clínica e funcional foram obtidos 92,7% de bons resultados. Encontrouse osteopenia em 24 acetábulos (44,4%) e 30 fêmures (55,6%). O desgaste do polietileno esteve presente em 43 acetábulos (79,6%), com média de dois milímetros (0-5mm). A análise estatística dos resultados sugeriu que a presença de osteopenias não está relacionada ao desfecho clínico (p=0,75); o desgaste do polietileno, bem como a presença de osteopenia, foi mais pronunciado nos pacientes abaixo de 55 anos (p<0,05). Concluímos que a utilização da prótese de Spotorno® nessa coorte apresentou bons resultados, semelhantes aos relatos prévios da literatura.pt_BR
dc.description.abstractThe objective of the study was to assess clinical-X-ray endpoint on a cohort of 48 patients (54 hips) submitted to Spotorno® primary non-cemented total hip arthroplasty in the last 20 years (1985 – 2005), with mean follow-up time of 17.5 years (range: 8-20 years). In the clinical and functional evaluation, 92.7% good outcomes were achieved. Osteopenia was found in 24 acetabula (44.4%) and 30 femurs (55.6%); A mean of 2 millimeters (0-5 mm) of polyethylene wear-off was present in 43 acetabula (79.6%). The statistical analysis of the results suggested that the presence of osteopenia is not associated to the clinical endpoint (p=0.75); polyethylene wear-off as well as the presence of osteopenia was more significant if patients below the age of 55 years (p<0.05). We concluded that the use of a Spotorno® prosthesis on this cohort showed god outcomes, similar to those previously reported in literature.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.relation.ispartofActa ortopedica brasileira. São Paulo : Redprint, 2005. Vol. 16, n. 4 (2008), p. 217-222pt_BR
dc.rightsOpen Accessen
dc.subjectArtroplastia de quadrilpt_BR
dc.subjectHip arthroplastyen
dc.subjectOrtopediapt_BR
dc.subjectSurgeryen
dc.subjectHipen
dc.titleArtroplastia total do quadril de spotornopt_BR
dc.title.alternativeSpotorno® total hip arthroplasty en
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb000716553pt_BR
dc.type.originNacionalpt_BR


Thumbnail
Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples