Artroplastia total do quadril de spotorno
dc.contributor.author | Macedo, Carlos Alberto de Souza | pt_BR |
dc.contributor.author | Scheidt, Rodrigo Benedet | pt_BR |
dc.contributor.author | Palma, Humberto Moreira | pt_BR |
dc.contributor.author | Rosito, Ricardo | pt_BR |
dc.contributor.author | Weissheimer Junior, Walmor | pt_BR |
dc.contributor.author | Galia, Carlos Roberto | pt_BR |
dc.date.accessioned | 2012-06-14T01:34:36Z | pt_BR |
dc.date.issued | 2008 | pt_BR |
dc.identifier.issn | 1413-7852 | pt_BR |
dc.identifier.uri | http://hdl.handle.net/10183/49666 | pt_BR |
dc.description.abstract | Uma coorte de 48 pacientes (54 quadris) submetidos a artroplastia total primária de quadril não-cimentada com prótese de Spotorno®. O objetivo do estudo foi avaliar o desfecho clínico-radiológico da prótese de Spotorno®,em um período de 20 anos (1985 a 2005), com seguimento médio de 17,5 anos (8-20anos). Na avaliação clínica e funcional foram obtidos 92,7% de bons resultados. Encontrouse osteopenia em 24 acetábulos (44,4%) e 30 fêmures (55,6%). O desgaste do polietileno esteve presente em 43 acetábulos (79,6%), com média de dois milímetros (0-5mm). A análise estatística dos resultados sugeriu que a presença de osteopenias não está relacionada ao desfecho clínico (p=0,75); o desgaste do polietileno, bem como a presença de osteopenia, foi mais pronunciado nos pacientes abaixo de 55 anos (p<0,05). Concluímos que a utilização da prótese de Spotorno® nessa coorte apresentou bons resultados, semelhantes aos relatos prévios da literatura. | pt_BR |
dc.description.abstract | The objective of the study was to assess clinical-X-ray endpoint on a cohort of 48 patients (54 hips) submitted to Spotorno® primary non-cemented total hip arthroplasty in the last 20 years (1985 – 2005), with mean follow-up time of 17.5 years (range: 8-20 years). In the clinical and functional evaluation, 92.7% good outcomes were achieved. Osteopenia was found in 24 acetabula (44.4%) and 30 femurs (55.6%); A mean of 2 millimeters (0-5 mm) of polyethylene wear-off was present in 43 acetabula (79.6%). The statistical analysis of the results suggested that the presence of osteopenia is not associated to the clinical endpoint (p=0.75); polyethylene wear-off as well as the presence of osteopenia was more significant if patients below the age of 55 years (p<0.05). We concluded that the use of a Spotorno® prosthesis on this cohort showed god outcomes, similar to those previously reported in literature. | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | por | pt_BR |
dc.relation.ispartof | Acta ortopedica brasileira. São Paulo : Redprint, 2005. Vol. 16, n. 4 (2008), p. 217-222 | pt_BR |
dc.rights | Open Access | en |
dc.subject | Artroplastia de quadril | pt_BR |
dc.subject | Hip arthroplasty | en |
dc.subject | Surgery | en |
dc.subject | Ortopedia | pt_BR |
dc.subject | Hip | en |
dc.title | Artroplastia total do quadril de spotorno | pt_BR |
dc.title.alternative | Spotorno® total hip arthroplasty | en |
dc.type | Artigo de periódico | pt_BR |
dc.identifier.nrb | 000716553 | pt_BR |
dc.type.origin | Nacional | pt_BR |
Files in this item
This item is licensed under a Creative Commons License
-
Journal Articles (40361)Health Sciences (10795)