Diagnostic accuracy of multiorgan point-of-care ultrasound compared with pulmonary computed tomographic angiogram in critically ill patients with suspected pulmonary embolism
Visualizar/abrir
Data
2022Autor
Tipo
Abstract
Background: Critically ill patients have a higher incidence of pulmonary embolism (PE) than non-critically ill patients, yet no diagnostic algorithm has been validated in this population, leading to the overuse of pulmonary artery computed tomographic angiogram (CTA). This study aimed to comparatively evaluate the diagnostic accuracy of point-of-care ultrasound (POCUS) combined with laboratory data versus CTA in predicting PE in critically ill patients. Methods: A prospective diagnostic accurac ...
Background: Critically ill patients have a higher incidence of pulmonary embolism (PE) than non-critically ill patients, yet no diagnostic algorithm has been validated in this population, leading to the overuse of pulmonary artery computed tomographic angiogram (CTA). This study aimed to comparatively evaluate the diagnostic accuracy of point-of-care ultrasound (POCUS) combined with laboratory data versus CTA in predicting PE in critically ill patients. Methods: A prospective diagnostic accuracy study. Critically ill patients with suspected acute PE undergoing CTA were prospectively enrolled. Demographic and clinical data were collected from electronic medical records. Blood samples were collected, and the Wells and revised Geneva scores were calculated. Standardized multiorgan POCUS and CTA were performed. The discriminatory power of multiorgan POCUS combined with biochemical markers was tested using ROC curves, and multivariate analysis was performed. Results: A total of 88 patients were included, and 37 (42%) had PE. Multivariate analysis showed a relative risk (RR) of PE of 2.79 (95% CI, 1.61-4.84) for the presence of right ventricular (RV) dysfunction, of 2.54 (95% CI, 0.89-7.20) for D-dimer levels >1000 ng/mL, and of 1.69 (95% CI, 1.12-2.63) for the absence of an alternative diagnosis to PE on lung POCUS or chest radiograph. The combination with the highest diagnostic accuracy for PE included the following variables: 1- POCUS transthoracic echocardiography with evidence of RV dysfunction; 2- lung POCUS or chest radiograph without an alternative diagnosis to PE; and 3- plasma D-dimer levels >1000 ng/mL. Combining these three findings resulted in an area under the curve of 0.85 (95% CI, 0.77-0.94), with 50% sensitivity and 96% specificity. Conclusions: Multiorgan POCUS combined with laboratory data has acceptable diagnostic accuracy for PE compared with CTA. The combined use of these methods might reduce CTA overuse in critically ill patients. ...
Contido em
PloS one. San Francisco. Vol. 17, no. 10 (Oct. 2022), e0276202, 11 p.
Origem
Estrangeiro
Coleções
-
Artigos de Periódicos (40305)Ciências da Saúde (10773)
Este item está licenciado na Creative Commons License