Reliability of knee extensor neuromuscular structure and function and functional tests’ performance
Visualizar/abrir
Data
2021Autor
Tipo
Assunto
Abstract
Introduction The aim of this study was to evaluate the intra and inter-rater and inter-analyzer reliability of neuromuscular variables and functional tests. Methods Cross-sectional crossover design. Two independent raters and analyzers evaluated twenty-two healthy subjects. Knee-extensor strength was assessed from three maximal voluntary isometric contractions. Muscle activation was obtained from the vastus lateralis (VL), rectus femoris (RF), and vastus medialis (VM) muscles. VL and RF muscles ...
Introduction The aim of this study was to evaluate the intra and inter-rater and inter-analyzer reliability of neuromuscular variables and functional tests. Methods Cross-sectional crossover design. Two independent raters and analyzers evaluated twenty-two healthy subjects. Knee-extensor strength was assessed from three maximal voluntary isometric contractions. Muscle activation was obtained from the vastus lateralis (VL), rectus femoris (RF), and vastus medialis (VM) muscles. VL and RF muscles’ architecture [fascicle length (FL), pennation angle (PA), muscle thickness (MT)] was obtained at rest by ultrasound. The time from five sit-to-stand (STS) trials, and the distance from the 6-min walk test (6MWT) were obtained. Intraclass correlation coefficient was determined and classified as strong (r = 0.75–1.00), moderate (r = 0.40–0.74), and weak (r < 0.40). Strong intra-rater reliability values were observed for strength (r = 0.97), muscle activation [VL (r = 0.91); RF (r = 0.92); VM (r = 0.80)], VL [FL (r = 0.90); PA (r = 0.94); MT (r = 0.99)] and RF [MT (r = 0.85)] muscle architecture, STS (r = 0.95), and 6MWT (r = 0.98). Inter-rater reliability also presented strong values for strength (r = 0.97), muscle activation [VL (r = 0.94); RF (r = 0.79); VM (r = 0.78)], muscle architecture VL [PA (r = 0.81) and MT (r = 0.88)] and RF [MT (r = 0.80)], STS (r = 0.93), and 6MWT (r = 0.98). A moderate correlation VL muscle architecture [FL (r = 0.69)]. Inter-analyzer muscle architecture reliability presented strong VL [FL (r = 0.77); PA (r = 0.76); MT (r = 0.91)] and RF [MT (r = 0.99)]. Conclusion The high intra and inter-rater and inter-analyzer reliability values for most variables is evidence that they can be used for clinical evaluation. Muscle architecture might need a longer training period by different raters and analyzers to increase reliability. ...
Contido em
Journal of bodywork and movement therapies. New York. Vol. 27, (July 2021), p. 584-590
Origem
Estrangeiro
Coleções
-
Artigos de Periódicos (39123)Ciências da Saúde (10549)
Este item está licenciado na Creative Commons License