dc.description.abstractO trabalho disserta sobre a investigação dos mecanismos de degradação da placa refratária utilizada no sistema de válvula gaveta, o qual controla o fluxo de aço líquido da panela da aciaria para o distribuidor. As placas estudadas eram do tipo Al2O3-ZrO2-C. Na investigação foram caracterizadas e analisadas placas novas e usadas. Também foi feito teste de corrosão estático para avaliação da interação química das placas com a escória proveniente do processo de refino secundário. Além disso, foi feito experimento em laboratório para avaliar o desgaste das placas devido a presença de resquícios de escória entre as placas no processo de abertura da válvula. Tal experimento foi realizado nos moldes do teste de resistência de argamassa usado por Leroy (EQUIPE DE FURNAS, 1997). Para tanto foram usadas técnicas de caracterização como Microscopia Eletrônica de Varredura (MEV), Espectroscopia de Dispersão em Energia (EDS), Fluorescência de raios x (FRX) e Difração de raios x (DRX). Por meio de análises foi possível propor explicações para os mecanismos de degradação, como a corrosão devido ao contato com a escória e a formação de desgaste em forma de lingueta devido ao uso de válvula semiaberta Principalmente, a partir dos experimentos realizados foi possível identificar um mecanismo de degradação ainda não abordado na literatura: o desgaste do material das placas ocasionado pela abertura da válvula gaveta quando as placas estão ligadas por escória solidificada. Devido à falta de metodologia específica para abordar esse tema, adotou-se um método usado para avaliar a resistência de cimetos e argamassas na investigação sobre a influência da adesão da escória na degradação das placas. Tal método, chamado de tração direta (L.A.Farias, 2016), mostrou uma degradação intensa das placas. A reação química entre a placa aluminosa e a escória é a responsável pela adesão entre as duas placas e a escória. A adesão por escória mostrou que pode ser tão resistente quanto a ligação entre as partículas do refratário, que teve partículas retiradas no teste de tração direta. Assim, conclui-se que a interação química entre a placa e a escória, aliada a movimentação de abre e fecha do conjunto de placas quando a escória já solidificou, são mecanismos importantes na degradação das placas Al2O3-ZrO2-C de válvula gaveta.pt_BR
dc.description.abstractThis master’s dissertation investigates the deterioration of one of the parts that make up the sliding gate system of a steelmaking ladle. This part controls the liquid steel flow from the ladle to the tundish. These parts are called plates and may be made of different refractory ceramic materials. However, the plates used in this study are made of Al2O3-ZrO2-C. New parts and after service parts were analyzed. A static corrosion test was performed to analyze the chemical interaction between the refractory plates and the slag derived from steelmaking refining process. A laboratory experiment was carried out to evaluate wear due to remnants of slag between the sliding gate plates during the opening and closing of the gate. Such experiment was performed based on Mortar Resistance test used by Leroy. To analyze the materials, characterization techniques such as Scan Electron Microscopy (SEM), Energy Dispersive Spectroscopy (EDS), X-ray fluorescence (XRF), and X-ray diffraction were used. Based on the results of these analyses, a series of deterioration mechanisms were presented, such as the corrosion due to slag contact, and intensification of wear due to the use of semi-open valve. Mainly, from the performed experiments it was possible to identify a deterioration mechanism, that has not been discussed in literature yet This wear mechanism happens when the sliding gate plates are bonded by solidified slag, which is caused by opened valves, and leads to the extraction of particles from the surface of the plates. Due the lack of methodology to evaluate this kind of deterioration mechanism, a methodology based on mortar testing was developed. This method, called direct tensile test (L.A.Farias, 2016), showed intense deterioration. The chemical reaction between aluminum oxide refractory plate and the slag is responsible for the adhesion between plates and slag. This adhesion may be as strong as adhesion between the particles of the refractory, since refactory particles were removed in the test. Thus, it was concluded that the chemical interaction between refractory plate and slag, alied to the opening and closing mechanism are important in the deterioration of the Al2O3-ZrO2-C plates of the slide gate of the ladle.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectDeterioration mechanismsen
dc.subjectMateriais refratáriospt_BR
dc.subjectPanela siderúrgicapt_BR
dc.subjectRefractoriesen
dc.subjectVálvula de gavetapt_BR
dc.subjectSteelmanking ladleen
dc.subjectSecondary refiningen
dc.subjectSliding gate valveen
dc.titleEstudo dos mecanismos de degradação de placa Al2O3-ZrO2-C de válvula gaveta em panela de aciariapt_BR
dc.typeDissertaçãopt_BR
dc.contributor.advisor-coBielefeldt, Wagner Vianapt_BR
dc.identifier.nrb001064834pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentEscola de Engenhariapt_BR
dc.degree.programPrograma de Pós-Graduação em Engenharia de Minas, Metalúrgica e de Materiaispt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2017pt_BR
dc.degree.levelmestradopt_BR