Mostrar registro simples

dc.contributor.advisorSilva, Jacqueline Arguello dapt_BR
dc.contributor.authorMedeiros, Natália Goedtelpt_BR
dc.date.accessioned2017-11-18T02:34:58Zpt_BR
dc.date.issued2017pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/170374pt_BR
dc.description.abstractNeste trabalho relata-se pela primeira vez a determinação de adenosina por um biossensor baseado em tirosinase. O biossensor foi desenvolvido mediante a modificação de um eletrodo de carbono impresso (SPE) com nanopartículas de ouro (AuNPs), tirosinase (Tyr) e Nafion, denominado biossensor Nafion/Tyr/AuNPs/SPE. As AuNPs sintetizadas possuem diâmetro médio de 15,0 ± 1,1 nm e sua função é melhorar a via de condução de elétrons entre a enzima e o eletrodo. Utilizou-se o aprisionamento com filme Nafion® para evitar a lixiviação enzimática da superfície do eletrodo. A tirosinase imobilizada apresentou boa atividade frente ao substrato catecol. Verificou-se que a adenosina atua como um inibidor do tipo não-competitivo. O biossensor é estável durante pelo menos 45 dias. Além disso, foi realizada a eletro-oxidação da adenosina para sua determinação. O biossensor apresenta sensibilidade superior em comparação com SPE, AuNPs/SPE e Nafion/AuNPs/SPE. As curvas de calibração revelaram duas faixas lineares para as concentrações de adenosina, de 1,0 × 10-5 mol L-1 até 5,0 × 10-5 mol L-1 e entre 6,0 × 10-5 mol L-1 e 1,2 × 10-4 mol L -1. O limite de detecção (3 × (desvio padrão + média dos brancos)/coeficiente angular da curva) foi de 7,0 × 10-7 mol L-1.pt_BR
dc.description.abstractIn this work we report for the first time the determination of adenosine by a biosensor based on tyrosinase. The biosensor was developed by modifying a screen-printed carbon electrode (SPE) with gold nanoparticles (AuNPs), tyrosinase (Tyr) and Nafion, denoted as Nafion/Tyr/AuNPs/SPE biosensor. The synthesized AuNPs have a mean diameter of 15.0 ± 1.1 nm and their function is to improve the electron conduction pathway between the enzyme and the electrode. The entrapment with Nafion® film was selected to prevent the enzyme lixiviation from the electrode surface. Immobilized tyrosinase showed good activity with the catechol substrate. It was found that adenosine acts as a non-competitive type inhibitor. The biosensor is stable for at least 45 days. In addition, the electro-oxidation of adenosine was performed for its determination. The biosensor has superior sensitivity compared to SPE, AuNPs/SPE and Nafion/AuNPs/SPE. Calibration curves revealed two linear ranges for adenosine concentrations of 1,010-5 mol L-1 up to 5,010-5 mol L-1 and from 6,010-5 mol L-1 to 1,210-4 mol L-1. The detection limit (3 × (standard deviation + mean of blanks)/slope of the curve) was 7,010-7 mol L-1.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectAdenosineen
dc.subjectAdenosinapt_BR
dc.subjectScreen-printed electrodeen
dc.subjectTirosinasept_BR
dc.subjectGold nanoparticlesen
dc.subjectBiossensorespt_BR
dc.subjectBiosensoren
dc.subjectTyrosinaseen
dc.titleDesenvolvimento de biossensor baseado em tirosinase para determinação de adenosinapt_BR
dc.typeDissertaçãopt_BR
dc.contributor.advisor-coKubota, Lauro Tatsuopt_BR
dc.identifier.nrb001021026pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentInstituto de Químicapt_BR
dc.degree.programPrograma de Pós-Graduação em Químicapt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2017pt_BR
dc.degree.levelmestradopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples