Mostrar registro simples

dc.contributor.advisorSilva, Marcia Messias dapt_BR
dc.contributor.authorAntunes, Greici Alvespt_BR
dc.date.accessioned2017-01-14T02:24:07Zpt_BR
dc.date.issued2014pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/150824pt_BR
dc.description.abstractEste trabalho propõe o desenvolvimento de método analítico para a determinação de Fe, Cu e Zn em amostras de biodiesel por espectrometria de absorção atômica com chama (F AAS), utilizando microemulsão como preparo de amostra. Neste trabalho buscou-se, para a formação da microemulsão, o uso de um solvente orgânico menos tóxico do que o solvente usado no método de referência (ABNT NBR 15556), o uso de padrões inorgânicos para a calibração e a ausência de um surfactante. A composição da microemulsão foi estudada através de um diagrama trifásico e a composição adotada foi de 1,7 g de biodiesel, 1,1 mL de H2O/HNO3 e volume completado com propan-1-ol até 10 mL. Foi utilizado ácido oleico e padrões inorgânicos no preparo das curvas analíticas. O método apresentou boa linearidade (R > 0,99) e desvios padrão menor do que 5%. Os LDs foram de 0,3, 0,1 e 0,07 mg kg-1 para os metais Fe, Cu e Zn, respectivamente. Esses resultados foram melhores do que os obtidos pelo método de referência devido a melhor precisão nas medidas no método proposto. Os resultados dos testes de recuperação (95-102%) indicam a ausência de efeitos de matriz. Os parâmetros obtidos pelo método proposto estão de acordo com os encontrados com o método padrão, o que torna o seu uso viável para a determinação de elementos traço. Para avaliar a exatidão do método foram comparados os resultados de amostras reais com o método de referência e também com o método de decomposição ácida. A aplicação do teste estatístico “t” student, mostrou que não existe diferença significativa entre os resultados obtidos pelos três métodos. Portanto, o uso de microemulsões aliado à técnica F AAS apresentou uma estratégia simples, rápida e prática, além da possibilidade de se utilizar solventes não carcinogênicos. A presença de ácido no meio permite maior disponibilidade e mobilidade dos analitos, evitando a adsorção nas paredes do recipiente além do uso de padrões aquosos na calibração para avaliar a presença de metais no biodiesel.pt
dc.description.abstractThis work proposes the development of an analytical method for the determination of Fe, Cu and Zn in biodiesel samples by flame atomic absorption spectrometry (F AAS) using microemulsion as sample preparation. The formation of the microemulsion using a less toxic organic solvent instead of the solvent used in the reference method (ABNT NBR 15556), inorganic standards for calibration and the absence of a surfactant was sought. The composition of the microemulsion was investyigated through a three phase diagram and the composition adopted was 1.7 g of biodiesel, 1.1 ml of H2O/HNO3 and completed with propan-1-ol to 10 mL volume. Oleic acid and inorganic standards was used to prepare the calibration curves. The method showed good linearity (R > 0.99) and less than 5% standard deviation. The Limits of Detection obtained were 0.3, 0.1 and 0.07 mg kg-1 for Fe, Cu and Zn, respectively. These results were better than those obtained by the reference method due to lower fluctuation in the measurements in the proposed method. The spike recoveries obtained (95-102%) indicate the absence of matrix effects. The parameters obtained for the proposed method are in agreement with those found for the standard method, which makes feasible its use for the determination of trace elements. In order to evaluate the accuracy of the method the results of real samples were compared with the reference method and also with the method of acid decomposition. The application of the statistic test "t" student showed no significant difference between the results obtained by the three test methods. Therefore, the use of the microemulsions combined with F AAS technique showed a simple, fast and practical strategy, besides the possibility of using non-carcinogenic solvents. The presence of acid in the medium allows greater freedom of analytes, preventing adsorption onto the walls of the container and the use of aqueous standards for evaluating the presence of metals in biodiesel.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectEspectrometria de absorção atômica com chamapt_BR
dc.subjectBiodieselen
dc.subjectMetais : Determinaçãopt_BR
dc.subjectMetalsen
dc.subjectÓleos lubrificantespt_BR
dc.subjectMicroemulsionen
dc.subjectF AASen
dc.titleDesenvolvimento de método para determinação de ferro, cobre e zinco em microemulsão de biodiesel por espectrometria de absorção atômica com chamapt_BR
dc.title.alternativeDevelopment of method for determination of iron, copper and zinc in biodiesel by flame atomic absorption spectrometry using microemulsion as sample preparation en
dc.typeDissertaçãopt_BR
dc.identifier.nrb001008454pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentInstituto de Químicapt_BR
dc.degree.programPrograma de Pós-Graduação em Químicapt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2014pt_BR
dc.degree.levelmestradopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples