Mostrar registro simples

dc.contributor.advisorBretas, Arturo Sumanpt_BR
dc.contributor.authorRodríguez Paz, Martín Cruzpt_BR
dc.date.accessioned2015-07-09T02:01:25Zpt_BR
dc.date.issued2015pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/118882pt_BR
dc.description.abstractDispositivos baseados em eletrônica de potência, conhecidos na literatura como Dispositivos FACTS (Flexible AC Transmission Systems) permitem aumentar a capacidade de transmissão diminuindo a margem de segurança necessária para uma operação segura do sistema elétrico de potência (SEP) sem construir novas linhas, permitindo controlar os fluxos nas linhas e assim permitindo que os contratos entre as empresas de transmissão sejam respeitados. Entre os dispositivos FACTS, o de maior versatilidade é o Unified Power Flow Controller (UPFC), capaz de controlar três variáveis do sistema. No entanto, a inclusão desses dispositivos traz outros problemas ao SEP, um deles, a proteção das linhas. Este trabalho apresenta uma contribuição para uma nova formulação matemática, adaptativa e compensada para a proteção de distância baseada na impedância aparente para a proteção de linhas compensadas com dispositivos UPFC. A formulação proposta se baseia em uma modelagem trifásica do sistema e na compensação da impedância aparente calculada através dos parâmetros controlados do UPFC e da estimação da impedância da falta. Resultados obtidos através da simulação exaustiva de faltas, mostram que esta formulação apresenta um excelente desempenho para a proteção de distância de linhas compensadas por dispositivos UPFC.pt_BR
dc.description.abstractPower electronics-based devices, known as FACTS devices (Flexible Alternating current Transmission Systems) allow to increase transmission capacity by decreasing the safety margin required for a secure operation of the Electric Power System (EPS). It is possible without need to build new lines, allowing to control the flows in lines and thus allowing contracts between the transmission companies are respected. Among the FACTS devices, the most versatile is the Unified Power Flow Controller (UPFC) capable of controlling three variables of the system. However, the inclusion of these devices brings other problems to the EPS, one of them, the transmission lines protection. This Thesis presents a contribution to a new mathematical formulation, adaptive and compensated for the distance protection based on the apparent impedance to protect transmission lines compensated by UPFC devices. The proposed formulation is based on a three-phase frame reference and the compensation of apparent impedance by the UPFC controlled parameters and the estimation of the fault impedance. Results obtained, through the comprehensive simulation of faults, show that it formulation present excellent performance for distance protection of transmission lines compensated by UPFC devices.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectDistance protectionen
dc.subjectSistema elétrico de potência : Proteçãopt_BR
dc.subjectImpedância elétricapt_BR
dc.subjectFACTSen
dc.subjectSimulação numéricapt_BR
dc.subjectUPFCen
dc.subjectLinhas de transmissãopt_BR
dc.subjectFault impedanceen
dc.subjectAdaptative relayingen
dc.titleContribuição para proteção de distância em linhas compensadas com dispositivos UPFCpt_BR
dc.typeTesept_BR
dc.identifier.nrb000967026pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentEscola de Engenhariapt_BR
dc.degree.programPrograma de Pós-Graduação em Engenharia Elétricapt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2015pt_BR
dc.degree.leveldoutoradopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples