Mostrar registro simples

dc.contributor.authorPaludo, Laurapt_BR
dc.contributor.authorSouza, Sophia Lopes dept_BR
dc.contributor.authorSó, Marcus Vinicius Reispt_BR
dc.contributor.authorRosa, Ricardo Abreu dapt_BR
dc.contributor.authorVier-Pelisser, Fabiana Vieirapt_BR
dc.contributor.authorDuarte, Marco Antonio Húngaropt_BR
dc.date.accessioned2014-04-18T01:52:49Zpt_BR
dc.date.issued2012pt_BR
dc.identifier.issn0103-6440pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/94536pt_BR
dc.description.abstractThe aim of this study was to evaluate in vivo the clinical applicability of two electronic apex locators (EALs) - Apex (Septodont) and iPex (NSK) - in different groups of human teeth by using radiography. The working lengths (WLs) of 100 root canals were determined electronically. The EAL to be used first was chosen randomly and a K-file was inserted into the root canal until the EAL display indicated the location of the apical constriction (0 mm). The K-file was fixed to the tooth and a periapical radiograph was taken using a radiographic film holder. The K-file was removed and the WL was measured. The same procedure was repeated using the other EAL. Radiographs were examined with the aid of a light-box with lens of ×4 magnification by two blinded experienced endodontists. The distance between the file tip and the root apex was recorded as follows: (A) +1 to 0 mm, (B) -0.1 to 0.5 mm, (C) -0.6 to 1 mm, (D) -1.1 to 1.5 mm, and (E) -1.6 mm or greater. For statistical purposes, these scores were divided into 2 subgroups according to the radiographic apex: acceptable (B, C, and D) and non-acceptable (A and E). Statistically significant differences were not found between the results of Apex and iPex in terms of acceptable and non-acceptable measurements (p>0.05) or in terms of the distance recorded from file tip and the radiographic apex (p>0.05). Apex and iPex EALs provided reliable measurements for WL determination for endodontic therapy.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoengpt_BR
dc.relation.ispartofBrazilian dental journal. Ribeirão Preto. Vol. 23, no. 1 (2012), p. 54-58pt_BR
dc.rightsOpen Accessen
dc.subjectworking lengthen
dc.subjectEndodontiapt_BR
dc.subjectRadiografia dentariapt_BR
dc.subjectradiographic apexen
dc.subjectCanais radicularespt_BR
dc.subjectelectronic apex locatoren
dc.titleAn in vivo radiographic evaluation of the accuracy of Apex and iPex Eletronic Apex Locatorspt_BR
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb000823210pt_BR
dc.type.originNacionalpt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples