Mostrar el registro sencillo del ítem
Lodenafil carbonate tablets : optimization and validation of a capillary zone electrophoresis method
dc.contributor.author | Codevilla, Cristiane Franco | pt_BR |
dc.contributor.author | Ferreira, Pâmela Cristina L. | pt_BR |
dc.contributor.author | Sangoi, Maximiliano da Silva | pt_BR |
dc.contributor.author | Froehlich, Pedro Eduardo | pt_BR |
dc.contributor.author | Bergold, Ana Maria | pt_BR |
dc.date.accessioned | 2014-03-01T01:54:38Z | pt_BR |
dc.date.issued | 2012 | pt_BR |
dc.identifier.issn | 0103-5053 | pt_BR |
dc.identifier.uri | http://hdl.handle.net/10183/88086 | pt_BR |
dc.description.abstract | Um método simples de eletroforese capilar de zona (CZE) foi desenvolvido e validado para análise de carbonato de lodenafila em comprimidos. A metodologia de superfície de resposta foi utilizada para a otimização do pH, concentração do tampão, voltagem e temperatura. O método utilizou como eletrólito, tampão borato 50 mmol L-1, pH 10, voltagem de 15 kV. A separação foi efetuada em capilar de sílica fundida mantida a 32,5 oC e o comprimento de onda de detecção foi de 214 nm. O método foi validado, demonstrando especificidade, linearidade (r = 0,9995), precisão (desvio padrão relativo inferior a 2%) e exatidão (99,95%). O método demonstrou ser robusto, através de avaliação por planejamento fatorial fracionário. O método CZE proposto foi aplicado com sucesso para a análise quantitativa de carbonato de lodenafila em comprimidos e os resultados, comparados com os métodos por cromatografia líquida de alta eficiência e espectrofotometria no ultravioleta, não apresentaram diferença significativa | pt_BR |
dc.description.abstract | A simple capillary zone electrophoresis (CZE) method was developed and validated for the analysis of lodenafil carbonate in tablets. Response surface methodology was used for optimization of the pH and concentration of the buffer, applied voltage and temperature. The method employed 50 mmol L-1 borate buffer at pH 10 as background electrolyte with an applied voltage of 15 kV. The separation was carried out in a fused-silica capillary maintained at 32.5 oC and the detection wavelength was 214 nm. The method was validated showing specificity, linearity (r = 0.9995), precision (relative standard deviation less than 2%) and accuracy (99.95%). The method proved to be robust by a fractional factorial design evaluation. The proposed CZE method was successfully applied for the quantitative analysis of lodenafil carbonate in tablets and the results compared to the high performance liquid chromatography and ultraviolet spectrophotometric methods, showed non-significant differences. | en |
dc.format.mimetype | application/pdf | pt_BR |
dc.language.iso | eng | pt_BR |
dc.relation.ispartof | Journal of the Brazilian Chemical Society. São Paulo. Vol. 23, n. 11 (nov. 2012), p. 2114-2121 | pt_BR |
dc.rights | Open Access | en |
dc.subject | capillary zone electrophoresis | en |
dc.subject | Carbonato de lodenafila | pt_BR |
dc.subject | experimental design | en |
dc.subject | Validação : Métodos de análise de fármacos | pt_BR |
dc.subject | Eletroforese capilar | pt_BR |
dc.subject | lodenafil carbonate | en |
dc.subject | optimization | en |
dc.subject | validation | en |
dc.title | Lodenafil carbonate tablets : optimization and validation of a capillary zone electrophoresis method | pt_BR |
dc.type | Artigo de periódico | pt_BR |
dc.identifier.nrb | 000904423 | pt_BR |
dc.type.origin | Nacional | pt_BR |
Ficheros en el ítem
Este ítem está licenciado en la Creative Commons License
-
Artículos de Periódicos (39951)Ciencias de la Salud (10685)