dc.description.abstractEste estudo visa a avaliar o efeito da fonte de luz na nanodureza, módulo de elasticidade, sorção de água e solubilidade de uma resina composta. Quatro unidades fotoativadoras foram utilizadas, três LED e uma halógnena. A resina composta foi utilizada para todos os testes. Para sorção de água e solubilidade, cinco discos de resina foram produzidos (15 mm em diâmetro e 1 mm em espessura), e foram polimerizados por 20 segundos em nove pontos diferentes (1 no centro e 8 ao redor). Para a avaliação de nanodureza e módulo de elasticidade, 20 cilindros (5 para cada grupo) foram confeccionados com uma matriz de aço bipartida (6,0 mm de diâmetro e 4,0 mm de espessura). Os resultados do estudo mostraram que o grupo polimerizado com a unidade fotoativadora Radii apresentou menor sorção de água que as outras unidades (p < 0,05). Nenhuma diferença estatística foi encontrada entre as unidades para nanodureza nos espécimes de 1mm de espessura. Entretanto, com um aumento da profundidade uma diminuição da nanodureza foi demonstrada (p < 0,05). Uma correlação positiva e forte foi demonstrada entre o modulo de elasticidade e a nanodureza para todos os grupos e profundidades. A fonte de luz influencia na sorção de água, nanodureza e módulo de elasticidade de resinas compostas.pt_BR
dc.description.abstractThe aim of this study was to evaluate the effect of a light source on nanohardness, elastic modulus, water sorption and solubility of a composite resin. Four curing units were used, three of which had an LED and another had a halogen source. The resin composite Z250 (3M ESPE) was used for all tests. For water sorption and solubility, five resin disks were made (15 mm in diameter and 1 mm thick), and these were polymerized for 20 seconds at nine different points (1 in the center and 8 around). For nanohardness and elastic modulus evaluation, 20 cylinders (5 for each group) were made with a bipartite steel matrix (6.0 mm diameter and 4.0 mm thick). The results of this study showed that the group polymerized with the Radii light-curing unit presented less water sorption than other curing units (p < 0.05). No statistical difference between units was found in nanohardness in 1mm-thick specimens. However, decreased nanohardness was shown at higher resin composite depth (p < 0.05). A Pearson correlation showed a strong positive relationship between nanohardness and elastic modulus for all groups and depths. The light source affects the water sorption, nanohardness and elastic modulus of composite resins.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoengpt_BR
dc.relation.ispartofPolímeros (São Carlos): ciência e tecnologia. São Carlos, SP. Vol. 21, no. 2 (2011), p. 103-106pt_BR
dc.rightsOpen Accessen
dc.subjectComposite resinen
dc.subjectResinas compostas : Fotopolimerizaveispt_BR
dc.subjectPolymerizationen
dc.subjectMateriais odontologicos : Avaliacaopt_BR
dc.subjectLight-curing uniten
dc.subjectNanohardnessen
dc.subjectElastic modulusen
dc.titleEffect of light sources on nanohardness, elastic modulus and water sorption of a composite resinpt_BR