Mostrar registro simples

dc.contributor.authorViecili, Raqueli Biscaynopt_BR
dc.contributor.authorSanches, Paulo Roberto Stefanipt_BR
dc.contributor.authorSilva, Denise Rossatopt_BR
dc.contributor.authorSilva Junior, Danton Pereira dapt_BR
dc.contributor.authorMuller, Andre Frottapt_BR
dc.contributor.authorMenna Barreto, Sérgio Saldanhapt_BR
dc.date.accessioned2012-07-18T01:35:36Zpt_BR
dc.date.issued2011pt_BR
dc.identifier.issn1806-3713pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/52936pt_BR
dc.description.abstractObjetivo: Identificar o papel do broncodilatador no tempo de apneia voluntária máxima em pacientes com distúrbios ventilatórios obstrutivos (DVOs). Métodos: Estudo caso-controle incluindo pacientes com DVOs e grupo controle. Foram realizadas espirometrias antes e após o uso de broncodilatador, assim como testes de apneia respiratória, utilizando-se um microprocessador eletrônico e um pneumotacógrafo como transdutor de fluxo. As curvas de fluxo respiratório foram exibidas em tempo real em um computador portátil, e os tempos de apneia voluntária inspiratória e expiratória máximos (TAVIM e TAVEM, respectivamente) foram determinados a partir do sinal adquirido. Resultados: Um total de 35 pacientes com DVOs e 16 controles foram incluídos no estudo. O TAVIM sem o uso de broncodilatador foi significativamente menor no grupo DVO que no grupo controle (22,27 ± 11,81 s vs. 31,45 ± 15,73; p = 0,025), mas essa diferença não foi significativa após o uso de broncodilatador (24,94 ± 12,89 s vs. 31,67 ± 17,53 s). Os valores de TAVEM foram significativamente menores no grupo DVO que no grupo controle antes (16,88 ± 6,58 s vs. 22,09 ± 7,95 s; p = 0,017) e após o uso de broncodilatador (21,22 ± 9,37 s vs. 28,53 ± 12,46 s; p = 0,024). Conclusões: Estes resultados fornecem uma evidência adicional da utilidade clínica do teste de apneia na avaliação da função pulmonar e do papel do broncodilatador nesse teste.pt_BR
dc.description.abstractObjective: To identify the role of bronchodilators in the maximal breath-hold time in patients with obstructive lung disease (OLD). Methods: We conducted a case-control study including patients with OLD and a control group. Spirometric tests were performed prior to and after the use of a bronchodilator, as were breath-hold tests, using an electronic microprocessor and a pneumotachograph as a flow transducer. Respiratory flow curves were displayed in real time on a portable computer. The maximal breath-hold times at end-inspiratory volume and at end-expiratory volume (BHTmaxVEI and BHTmaxVEE, respectively) were determined from the acquired signal. Results: A total of 35 patients with OLD and 16 controls were included. Prior to the use of a bronchodilator, the BHTmaxVEI was significantly lower in the OLD group than in the control group (22.27 ± 11.81 s vs. 31.45 ± 15.73 s; p = 0.025), although there was no significant difference between the two groups in terms of the post-bronchodilator values (24.94 ± 12.89 s vs. 31.67 ± 17.53 s). In contrast, BHTmaxVEE values were significantly lower in the OLD group than in the control group, in the pre- and post-bronchodilator tests (16.88 ± 6.58 s vs. 22.09 ± 7.95 s; p = 0.017; and 21.22 ± 9.37 s vs. 28.53 ± 12.46 s; p = 0.024, respectively). Conclusions: Our results provide additional evidence of the clinical usefulness of the breath-hold test in the assessment of pulmonary function and add to the existing knowledge regarding the role of the bronchodilator in this test.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.relation.ispartofJornal brasileiro de pneumologia. Brasília. Vol. 37, n. 6 (2011), p. 745-751pt_BR
dc.rightsOpen Accessen
dc.subjectTestes de função respiratóriapt_BR
dc.subjectRespiratory function testsen
dc.subjectPulmonary diseaseen
dc.subjectDoença pulmonar obstrutiva crônicapt_BR
dc.subjectBroncodilatadorespt_BR
dc.subjectChronic obstructiveen
dc.subjectBronchodilator agentsen
dc.subjectApnéiapt_BR
dc.subjectApneaen
dc.titleEfeito do broncodilatador no tempo de apneia voluntária máxima em pacientes com distúrbios ventilatórios obstrutivos=Bronchodilator effect on maximal breath-hold time in patients with obstructive lung diseasept_BR
dc.title.alternativeBronchodilator effect on maximal breath-hold time in patients with obstructive lung disease en
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb000822304pt_BR
dc.type.originNacionalpt_BR


Thumbnail
Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples