Standardization of method for determining glycosylated hemoglobin (Hb A1c) by cation exchange high performance liquid chromatography
dc.contributor.author | Antunes, Marina Venzon | pt_BR |
dc.contributor.author | Wagner, Sandrine Comparsi | pt_BR |
dc.contributor.author | Camargo, Joiza Lins | pt_BR |
dc.contributor.author | Linden, Rafael | pt_BR |
dc.date.accessioned | 2012-05-09T01:23:41Z | pt_BR |
dc.date.issued | 2009 | pt_BR |
dc.identifier.issn | 1984-8250 | pt_BR |
dc.identifier.uri | http://hdl.handle.net/10183/40409 | pt_BR |
dc.description.abstract | A hemoglobina A1c é o parâmetro laboratorial mais importante no monitoramento do controle metabólico de pacientes portadores de diabetes melito. Dentre as metodologias existentes para a quantificação desta fração de hemoglobina, a cromatografia líquida de alta eficiência (CLAE) baseada em troca catiônica apresenta a melhor precisão, sendo o método de escolha. O objetivo deste trabalho foi adaptar o método Mono S a um sistema de CLAE convencional permitindo a disponibilidade da determinação altamente seletiva de Hb A1c sem a aquisição de kits e comparar os resultados obtidos com o método imunoturbidimétrico Tinaquant® (Roche®) e com o método de cromatografia líquida Bio-Rad Variant®. O método desenvolvido apresentou precisão intra-ensaio de 1,39-3,65% e inter-ensaio de 2,80-3,02%. Os coeficientes de determinação entre os métodos foram: CLAE Mono S x Tinaquant®: r2 = 0,9856 (n=60) e CLAE Mono S x Bio-Rad Variant®: r2 = 0,9806 (n=16). Não foram observadas diferenças entre CLAE Mono S e Bio-Rad Variant® através de gráfico de Bland-Altman e regressão de Passing-Bablok. Foi obtida uma equação de conversão entre os valores do método teste e os valores obtidos por métodos rastreáveis ao National Glycohemoglobin Standardization Program (NGSP), permitindo a obtenção de valores comparáveis e intercambiáveis entre as metodologias com o uso de instrumentos convencionais de CLAE e com custo reduzido. | pt_BR |
dc.description.abstract | Hemoblobin A1c is the most important parameter for the monitoring of metabolic control of patients with diabetes mellitus. The purpose of this study was to adapt the Mono S method to a conventional HPLC system, allowing highly selective HbA1c determination without the acquisition of kits or the use of dedicated systems The results obtained were compared to the Tinaquant® immune turbidimetric method and the Bio- Rad Variant® chromatographic method. The developed method presented intra-study precision (C.V. %) of 1.39-3.65 and inter-study precision (C.V. %) of 2.80-3.02%. The determination coefficients among methods were: HPLC Mono S x Tinaquant®: r2: 0.9856 (n=60) and HPLC Mono S x HPLC Bio-Rad Variant®: r2: 0.9806 (n=16). A conversion equation between HPLC Mono S and Bio-Rad Variant® was calculated allowing yielding comparable and interchangeable values. The HPLC Mono-S is a precise, low-cost method which yields similar values to the Bio-Rad Variant® method on conventional HPLC equipment. yields similar values to the Bio-Rad Variant® method on conventional HPLC equipment. | en |
dc.format.mimetype | application/pdf | pt_BR |
dc.language.iso | eng | pt_BR |
dc.relation.ispartof | Brazilian journal of pharmaceutical sciences. São Paulo. Vol. 45, n. 4 (out./dez. 2009), p. 651-657 | pt_BR |
dc.rights | Open Access | en |
dc.subject | High performance liquid chromatography | en |
dc.subject | Cromatografia líquida de alta pressão | pt_BR |
dc.subject | Hemoglobinas glicadas | pt_BR |
dc.subject | Mono S | en |
dc.subject | Hemoglobin | en |
dc.title | Standardization of method for determining glycosylated hemoglobin (Hb A1c) by cation exchange high performance liquid chromatography | pt_BR |
dc.type | Artigo de periódico | pt_BR |
dc.identifier.nrb | 000766898 | pt_BR |
dc.type.origin | Nacional | pt_BR |
Este item está licenciado na Creative Commons License
-
Artigos de Periódicos (41387)Ciências da Saúde (11113)