Mostrar registro simples

dc.contributor.authorAraújo, Gustavo Neves dept_BR
dc.contributor.authorMachado, Guilherme Pinheiropt_BR
dc.contributor.authorMoura, Marciapt_BR
dc.contributor.authorSilveira, Anderson Donelli dapt_BR
dc.contributor.authorBergoli, Luiz Carlos Corsettipt_BR
dc.contributor.authorFuchs, Felipe Costapt_BR
dc.contributor.authorGonçalves, Sandro Cadavalpt_BR
dc.contributor.authorWainstein, Rodrigo Vugmanpt_BR
dc.contributor.authorLemos, Pedro A.pt_BR
dc.contributor.authorQuadros, Alexandre Schaan dept_BR
dc.contributor.authorWainstein, Marco Vugmanpt_BR
dc.date.accessioned2026-02-21T07:58:55Zpt_BR
dc.date.issued2023pt_BR
dc.identifier.issn0066-782Xpt_BR
dc.identifier.urihttp://hdl.handle.net/10183/301785pt_BR
dc.description.abstractFundamento: O padrão-ouro atual dos stents farmacológicos (SF) coronários consiste em ligas metálicas com hastes mais finas e polímeros bioabsorvíveis. Objetivos: Nosso objetivo foi comparar um stent eluidor de sirolimus de hastes ultrafinas (Inspiron®) com outras plataformas de SF de terceira geração em pacientes com infarto do miocárdio com supradesnivelamento do segmento ST (IAMCSST) submetidos à intervenção coronária percutânea (ICP) primária. Métodos: Analisamos dados de um registro multicêntrico de IAMCSST de centros de referência da Região Sul do Brasil. Todos os pacientes foram submetidos à ICP primária, seja com Inspiron® ou outro SF de segunda ou terceira geração. Foi calculado pareamento por escore de propensão (PEP) para gerar grupos semelhantes (Inspiron® versus outros stents) em relação às características clínicas e do procedimento. Todos os testes de hipótese tiveram um nível de significância bilateral de 0,05. Resultados: De janeiro de 2017 a janeiro de 2021, 1.711 pacientes foram submetidos à ICP primária, e 1.417 pacientes preencheram nossos critérios de inclusão (709 pacientes no grupo Inspiron® e 708 pacientes no grupo dos outros SF de segunda ou terceira geração). Após PEP, a amostra do estudo foi composta por 706 pacientes (353 pacientes no grupo Inspiron® e 353 pacientes no grupo dos demais SF de segunda ou terceira geração). As taxas de revascularização do vaso alvo (odds ratio [OR] 0,52; intervalo de confiança [IC] 0,21 a 1,34; p = 0,173), trombose de stent (OR 1,00; IC 0,29 a 3,48; p = 1,000), mortalidade (hazard ratio 0,724; IC 0,41 a 1,27; p = 0,257) e os desfechos cardiovasculares maiores (OR 1,170; IC 0,77 a 1,77; p = 0,526) foram semelhantes entre os grupos após um acompanhamento mediano de 17 meses. Conclusão: Nossos achados mostram que o stent Inspiron® foi eficaz e seguro quando comparado a outros SF de segunda ou terceira geração em uma coorte contemporânea do mundo real de pacientes com IAMCSST submetidos à ICP primária.pt_BR
dc.description.abstractBackground: The current gold standard of coronary drug-eluting stents (DES) consists of metal alloys with thinner struts and bioresorbable polymers. Objectives: Our aim was to compare an ultrathin strut, sirolimus-eluting stent (Inspiron®) with other third-generation DES platforms in patients with ST-elevation myocardial infarction (STEMI) submitted to primary percutaneous coronary intervention (PCI). Methods: We analyzed data from a STEMI multicenter registry from reference centers in the South Region of Brazil. All patients were submitted to primary PCI, either with Inspiron® or other second- or third-generation DES. Propensity score matching (PSM) was computed to generate similar groups (Inspiron® versus other stents) in relation to clinical and procedural characteristics. All hypothesis tests had a two-sided significance level of 0.05. Results: From January 2017 to January 2021, 1711 patients underwent primary PCI, and 1417 patients met our entry criteria (709 patients in the Inspiron® group and 708 patients in the other second- or third-generation DES group). After PSM, the study sample was comprised of 706 patients (353 patients in the Inspiron® group and 353 patients in the other the other second- or third-generation DES group). The rates of target vessel revascularization (OR 0.52, CI 0.21 – 1.34, p = 0.173), stent thrombosis (OR 1.00, CI 0.29 – 3.48, p = 1.000), mortality (HR 0.724, CI 0.41 – 1.27, p = 0.257), and major cardiovascular outcomes (OR 1.170, CI 0.77 – 1.77, p = 0.526) were similar between groups after a median follow-up of 17 months. Conclusion: Our findings show that Inspiron® was effective and safe when compared to other second- or third-generation DES in a contemporary cohort of real-world STEMI patients submitted to primary PCI.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.relation.ispartofArquivos brasileiros de cardiologia. São Paulo. Vol. 120, n. 6 (2023), e20220594, 9 p.pt_BR
dc.rightsOpen Accessen
dc.subjectMyocardial infarctionen
dc.subjectInfarto do miocárdiopt_BR
dc.subjectAngioplastyen
dc.subjectAngioplastiapt_BR
dc.subjectDrug-eluting stentsen
dc.subjectStents farmacológicospt_BR
dc.titleAvaliação no mundo real de um stent eluidor de sirolimus de hastes ultrafinas em pacientes com infarto do miocárdio com supradesnivelamento do segmento ST submetidos à intervenção coronária percutânea primária (Registro INSTEMI)pt_BR
dc.title.alternativeReal-world assessment of an ultrathin strut, sirolimus-eluting stent in patients with ST-elevation myocardial infarction submitted to primary percutaneous coronary intervention (INSTEMI Registry) en
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb001297712pt_BR
dc.type.originNacionalpt_BR


Thumbnail
Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples