Mostrar el registro sencillo del ítem

dc.contributor.advisorCosta, Sady Selaimen dapt_BR
dc.contributor.authorRuschel, Nathany Limapt_BR
dc.date.accessioned2024-08-09T06:47:03Zpt_BR
dc.date.issued2021pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/277143pt_BR
dc.description.abstractOBJETIVO: identificar a existência de relação entre achados audiométricos, timpanometria convencional e absorvância acústica na otite média com efusão. MÉTODO: Estudo transversal, prospectivo e observacional, sendo incluídos na amostra pacientes diagnosticados com otite média com efusão, por meio de exame audiológico e timpanometria convencional e de banda larga, para avaliar a aplicabilidade do segundo teste para o diagnóstico da referida alteração. RESULTADOS: Foram incluídos na amostra 29 indivíduos com idades entre 6 e 18 anos (média 11 ± 4,1 anos), sendo 15 (51,7%) do sexo feminino. Optou-se por fazer a análise por orelhas. Verificou-se que das 58 orelhas analisadas, 13 (21,4%) apresentaram limiares auditivos normais e 45 (78,6%) perda auditiva condutiva. Destas, na timpanometria convencional, 17,2% apresentaram curva timpanométrica do tipo “A”; 67,2%, do tipo “B”; 15,5%, do tipo “C”. Na TBL, o grupo com perda auditiva condutiva apresentou diminuição na absorvância a partir da frequência de 3000Hz, característica que não ocorreu no grupo com limiares normais. CONCLUSÃO: O estudo evidenciou que, na presença de perda auditiva condutiva, houve diminuição da absorvância acústica nas frequências de 250Hz, 4000Hz e 6000Hz. Quando avaliada a orelha contralateral, houve diminuição nas frequências de 4.000Hz e 6.000Hz. A timpanometria de banda larga apresentou alta especificidade e sensibilidade em orelhas com perda auditiva condutivas.pt_BR
dc.description.abstractOBJECTIVE:to identify the existence of a relationship between audiometric findings, conventional tympanometry and acoustic absorbance in otitis media with effusion. METHOD: Cross-sectional, prospective and observational study, being included in the sample with diagnosis and measurement, with great otitis media, for evaluation of audiological exams, to evaluate the applicability of the test or conventional measurement. RESULTS: Twenty-nine and 15-year-old females (mean 11 ±4 years) were included in the sample, of which 51.7% were female. An analysis by ears was chosen. It was found that 58 ears, 13 (21.4%) had normal hearing disorders and 45 (78.6%) had conductive hearing. Of these, in conventional tympanometry, 17.2% had type “A” tympanometric curvature; 67.2%, type “B”; 15.5%, type “C”. In TBL, the group with conductive hearing showed an increase in absorption from the frequency of 3000Hz, a characteristic that did not occur in the group with normal thresholds. CONCLUSION: The study showed that, in the presence of conductive hearing, there was an increase in acoustic absorbance at frequencies of 250Hz, 4000Hz and 6000Hz. When. the contralateral ear, there was an increase in frequencies of 6,000Hz Broadband tympanometry showed high specificity and sensitivity in ears with conductive hearing.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectHearingen
dc.subjectAudiçãopt_BR
dc.subjectTestes de impedância acústicapt_BR
dc.subjectHearing testsen
dc.subjectOtite médiapt_BR
dc.subjectOtitisen
dc.titleTimpanometria de banda larga em pacientes com otite média com efusão atendidos em ambulatório especializado no sul do Brasilpt_BR
dc.typeDissertaçãopt_BR
dc.contributor.advisor-coTeixeira, Adriane Ribeiropt_BR
dc.identifier.nrb001207887pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Medicinapt_BR
dc.degree.programPrograma de Pós-Graduação em Saúde da Criança e do Adolescentept_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2021pt_BR
dc.degree.levelmestradopt_BR


Ficheros en el ítem

Thumbnail
   

Este ítem está licenciado en la Creative Commons License

Mostrar el registro sencillo del ítem