Mostrar registro simples

dc.contributor.authorSaadi, Rodrigo Petersenpt_BR
dc.contributor.authorTagliari, Ana Paulapt_BR
dc.contributor.authorSaadi, Eduardo Kellerpt_BR
dc.contributor.authorMiglioranza, Marcelo Haertelpt_BR
dc.contributor.authorPolanczyk, Carisi Annept_BR
dc.date.accessioned2024-03-05T04:36:52Zpt_BR
dc.date.issued2022pt_BR
dc.identifier.issn2077-0383pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/272886pt_BR
dc.description.abstractTranscatheter aortic valve replacement (TAVR) is a well-established treatment option for patients with severe symptomatic aortic stenosis (AS) whose procedural efficacy and safety have been continuously improving. Appropriate preprocedural planning, including aortic valve annulus measurements, transcatheter heart valve choice, and possible procedural complication anticipation is mandatory to a successful procedure. The gold standard for preoperative planning is still to perform a multi-detector computed angiotomography (MDCT), which provides all the information required. Nonetheless, 3D echocardiography and magnet resonance imaging (MRI) are great alternatives for some patients. In this article, we provide an updated comprehensive review, focusing on preoperative TAVR planning and the standard steps required to do it properly.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoengpt_BR
dc.relation.ispartofJournal of clinical medicine. Basel, Switzerland. Vol. 11, no. 9 (May 2022), 2582, 14 p.pt_BR
dc.rightsOpen Accessen
dc.subjectTAVRen
dc.subjectSubstituição da valva aórtica transcateterpt_BR
dc.subjectTomografia computadorizada multidetectorespt_BR
dc.subjectSizingen
dc.subjectPlanningen
dc.subjectEcocardiografia tridimensionalpt_BR
dc.subjectMDCTen
dc.subjectImageamento por ressonância magnéticapt_BR
dc.subject3D echocardiographyen
dc.subjectMRIen
dc.titlePreoperative TAVR Planning : How to Do Itpt_BR