Mostrar el registro sencillo del ítem
Determination of fluoride in coal using pyrohydrolysis for analyte separation
dc.contributor.author | Dressler, Valderi L. | pt_BR |
dc.contributor.author | Pozebon, Dirce | pt_BR |
dc.contributor.author | Flores, Éder L.M. | pt_BR |
dc.contributor.author | Paniz, José Neri Gottfried | pt_BR |
dc.contributor.author | Flores, Erico Marlon de Moraes | pt_BR |
dc.date.accessioned | 2010-07-13T04:18:38Z | pt_BR |
dc.date.issued | 2003 | pt_BR |
dc.identifier.issn | 0103-5053 | pt_BR |
dc.identifier.uri | http://hdl.handle.net/10183/24524 | pt_BR |
dc.description.abstract | É proposto um método para a determinação de fluoreto em carvão mineral. O mesmo é baseado no emprego da pirohidrólise para a separação do fluoreto da amostra e posterior determinação do analito por potenciometria direta, com eletrodo íon seletivo. O sistema utilizado para a realização da pirohidrólise foi desenvolvido e a influência do V2O5 como catalisador na reação de pirohidrólise foi investigada, sendo verificado que o mesmo não influencia sobre a liberação do fluoreto presente na amostra. Amostras certificadas e não certificadas de carvão mineral foram analisadas. Resultados precisos (desvio padrão relativo inferior a 7%) e exatos (recuperação do fluoreto de acordo com os valores certificados) foram obtidos. O limite de quantificação (LOQ) do método foi de 5,0 μgF/g de amostra, usando 20 mg de amostra e volume final de 10 mL. A freqüência de análise foi de 5 amostras h-1 | pt_BR |
dc.description.abstract | A method for the determination of fluoride in coal using pyrohydrolysis for sample decomposition is proposed. An apparatus was constructed, and the influence of vanadium pentoxide (V2O5) as a catalyst for the pyrohydrolysis reaction was investigated. It was verified that V2O5 does not influence the release of fluoride from coal. Certified and non-certified samples were analysed using an ion selective electrode (ISE) for analyte detection. Precise (RSD < 7%) and accurate (recovery in accordance with certified values) results were obtained. The limit of quantification (LOQ) of the method was 5.0 μgF/g of sample, using 20 mg of sample and a final dilution to 10 mL. The sample frequency was 5 samples h-1. | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | eng | pt_BR |
dc.relation.ispartof | Journal of the Brazilian Chemical Society. São Paulo. Vol. 14, n. 2 (mar./abr. 2003), p. 334-338 | pt_BR |
dc.rights | Open Access | en |
dc.subject | Elementos-traço : Determinação | pt_BR |
dc.subject | Coal | en |
dc.subject | Fluoride | en |
dc.subject | Carvão : Análise química | pt_BR |
dc.subject | Pirohidrólise | pt_BR |
dc.subject | Pyrohydrolysis | en |
dc.subject | Ion electrode | en |
dc.subject | Vanadium pentoxide | en |
dc.subject | Catalyst | en |
dc.title | Determination of fluoride in coal using pyrohydrolysis for analyte separation | pt_BR |
dc.type | Artigo de periódico | pt_BR |
dc.identifier.nrb | 000358591 | pt_BR |
dc.type.origin | Nacional | pt_BR |
Ficheros en el ítem
Este ítem está licenciado en la Creative Commons License
-
Artículos de Periódicos (41542)Ciencias Exactas y Naturales (6257)