dc.description.abstractA construção civil consome 50% dos recursos naturais e 40% dos insumos energéticos mundiais. Boa parte desses impactos está atribuída às edificações. No âmbito de Habitação de Interesse Social (HIS) brasileira, o programa Minha Casa, Minha Vida se destaca com mais de 4 milhões de unidades entregues. Entretanto, pouca atenção é dada ao impacto ambiental e ao consumo energético dessas HISs. Desde 2013, as novas edificações habitacionais devem atender aos requisitos de Desempenho Térmico (DT) da NBR 15.575. Sabe-se que o DT está relacionado à eficiência termoenergética de edificações, sendo o Sistema de Cobertura (SC) um ponto chave para essa melhoria. Visto isso, este trabalho objetiva quantificar impactos ambientais incorporados ao ciclo de vida (berço ao portão) de SCs usuais do setor de HIS brasileiro, considerando SCs de mesmo DT de acordo com a NBR 15.575. Abordam-se 4 cenários base representativos de HISs e 4 cenários onde foi proposta a inclusão do isolante térmico Poliestireno Expandido (EPS), visando melhorar o DT dos SCs. Sete categorias de impacto são avaliadas utilizando para cálculo o software OpenLCA v.1.9. Resultados apontam que SCs com materiais cimentícios em sua composição são mais impactantes, sendo o aumento médio nos impactos devido à inclusão de EPS de 15%.pt_BR
dc.description.abstractConstruction industry consumes 50% of world natural resources and 40% of world energy inputs. In the Brazilian Social Housing (SH) context, My House My Life program stands out with over 4 million units handed in. However, little attention is paid to the environmental impact and energy consumption of these SHs. Since 2013, Brazilian new residential buildings must meet NBR 15.575 Thermal Performance (TP) requirements. It is known that the TP relates to the thermo-energetic efficiency of buildings, and the Roofing System (RS) is a key point for improvements. Therefore, this work aims to quantify the life cycle embodied environmental impacts (cradle-to-gate) of common RS adopted in Brazilian SHs, considering RSs with the same TP according to NBR 15.575. Four SH representative base scenarios are studied alongside with another four scenarios where the inclusion of Expanded Polystyrene (EPS), a thermal insulator, was proposed aiming to improve the TP of the RSs. Seven impact categories are evaluated using OpenLCA v.1.9 software for calculation. Results indicate that RSs with cementitious materials in their composition are more impactful, as the average increase in impacts due to the inclusion of EPS revolves around 15%.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectEngenharia civilpt_BR
dc.subjectLife cycle sssessmenten
dc.subjectRoofing system.en
dc.subjectAvaliação do ciclo de vidapt_BR
dc.subjectImpacto ambientalpt_BR
dc.subjectEnvironmental impacten
dc.subjectDesempenho térmicopt_BR
dc.subjectThermal performanceen
dc.subjectThermal insulationen
dc.titleAvaliação dos impactos ambientais do ciclo de vida e do desempenho térmico de sistemas de cobertura usuais em habitações de interesse socialpt_BR
dc.title.alternativeAssessment of life-cycle environmental impacts and of thermal performance of roofing systems used in social housing en
dc.typeTrabalho de conclusão de graduaçãopt_BR
dc.identifier.nrb001111390pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentEscola de Engenhariapt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2019pt_BR
dc.degree.graduationEngenharia Civilpt_BR
dc.degree.levelgraduaçãopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples