Show simple item record

dc.contributor.authorRovedder, Paula Maria Eidtpt_BR
dc.contributor.authorFernandes, Rafael Oliveirapt_BR
dc.contributor.authorJacques, Patrícia Santospt_BR
dc.contributor.authorZiegler, Brunapt_BR
dc.contributor.authorAndrade, Francini Porcherpt_BR
dc.contributor.authorDalcin, Paulo de Tarso Rothpt_BR
dc.date.accessioned2021-08-27T04:18:24Zpt_BR
dc.date.issued2020pt_BR
dc.identifier.issn2045-2322pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/226228pt_BR
dc.description.abstractNon-cystic fbrosis bronchiectasis (NCFB) is a chronic lung disease characterized by progressive and irreversible changes of the bronchial tree. The evaluation of exercise capacity is essential to manage this disease. This study aims to determine the within-subject repeatability of two Six Minute Walk Test (6MWT) in adults with NCFB. NCFB. This cross-sectional observational study included 66 NCFB subjects above 18 years-old (mean of 55 ± 17 years old, 68% women). 73% of the participants presented moderate to severe clinical condition classifed by Bronchiectasis Severity Index. It showed that these participants walked 16.6 m less (95%CI 3.8 to 29.4; p< 0.01) in the second 6MWT when compared to the frst test, with a within-subject coefcient variation of 9.4% (95%CI 7.2–11.2%) and an intra-test reliability with a high intraclass correlation coefcient of 0.88 (95%CI 0.80–0.93). Bland–Altman plot showed an agreement regarding test repeatability, besides presented a large limit of agreement (− 85 to 116 m). Respiratory rate and systolic blood pressure were signifcantly higher before starting the second test. In conclusion, 6MWT seems to be reproducible in NCFB subjects and vital sign verifcation should be attentively checked to assess if the patient is fully recovered to perform a second test, as well as the disease severity score. Other studies on this matter should be conducted with a larger number of participants to confrm the fndings of the present study.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoengpt_BR
dc.relation.ispartofScientific reports. London. Vol. 10 (2020), 19162, 8 p.pt_BR
dc.rightsOpen Accessen
dc.subjectTeste de caminhadapt_BR
dc.subjectBronquiectasiapt_BR
dc.subjectFibrose pulmonarpt_BR
dc.titleRepeatability of the 6-min walk test in non-cystic fibrosis bronchiectasispt_BR
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb001129641pt_BR
dc.type.originEstrangeiropt_BR


Files in this item

Thumbnail
   

This item is licensed under a Creative Commons License

Show simple item record