Mostrar el registro sencillo del ítem
Estudo comparativo da viabilidade miocárdica em áreas dissinérgicas ao ecocardiograma basal : cintilografia tomográfica com Tecnécio 99m-mibi sob baixa dose de Dobutamina versus Tálio em repouso-redistribuição
dc.contributor.advisor | Torres, Marco Antonio Rodrigues | pt_BR |
dc.contributor.author | Pilger Filho, Egon Pedro | pt_BR |
dc.date.accessioned | 2007-06-06T17:20:23Z | pt_BR |
dc.date.issued | 2000 | pt_BR |
dc.identifier.uri | http://hdl.handle.net/10183/2137 | pt_BR |
dc.description.abstract | A cintilografia com radioisótopos em repouso tem despertado muito interesse nos últimos anos para pesquisa da viabilidade miocárdica na disfunção isquêmica avançada do VE, porque esta pode ser reversível e porque há melhora prognóstica neste contexto. O objetivo desse trabalho é buscar identificar a acurácia da cintilografia tomográfica Tc-99m-Sestamibi, sob a infusão de dobutamina em baixa dose. Foram protocolados trinta pacientes que sofreram um infarto do miocárdio com padrão “Q”, com dissinergia ao ecocardiograma, e submetidos a estudos perfusionais em dias diferentes, com Tc-99m-Sestamibi − dobutamina e Tl-201 em repouso-redistribuição 4 horas, usado como padrão ouro. Não ocorreram complicações com nenhum paciente submetido ao protocolo do estudo. Os resultados revelaram: sensibilidade = 85%, especificidade = 87%, valor preditivo positivo = 96%, valor preditivo negativo = 65 % e acurácia de = 85,2%. A razão de probabilidade positiva foi de 6,68 e a razão de probabilidade negativa de 0,17. Confrontando-se nossos dados com uma metanálise de resultados para o Tc-99m-Sestamibi em repouso, a sensibilidade no presente estudo foi 85% vs. 81% e a especificidade de 87% vs. 60%. Em relação aos dados da literatura para Tl-201: 85% vs. 90% e 87% vs. 54%, sensibilidade e especificidade, respectivamente. Em conclusão, o Tc-99m-Sestamibi sob a infusão de dobutamina parece ser um método promissor para detectar viabilidade superior a esta modalidade de cintilografia em repouso, com valores preditivos comparáveis à literatura disponível para esse mesmo método: 85,2% vs. 87%, 96% vs. 90% e 65% vs. 83%, para acurácia, valor preditivo positivo e valor preditivo negativo, respectivamente. | pt_BR |
dc.description.abstract | Rest isotopic scintigraphy has been evoked much interest in the last years for myocardial viability search on severe ischemic ventricular dysfunction, because improvement of function can bring a better outcome to this subset of acute myocardial infarction (MI) survivors. This study was designed to search to identify accuracy of 99m-Tc sestamibi − low dose dobutamine SPECT scintigraphy in a single injection rest protocol examination. Thirty patients with previous Q wave (MI), with basal echocardiographic demonstration of rest dyssynergia and coronary artery related significant obstruction, were submitted to perfusion studies, on a different day basis, with 99m-Tc-sestamibi − dobutamine and 201-Th rest-redistribution, utilized as gold standard. There were not complications with any patient submitted to this study protocol. The results showed sensitivity = 85%, specificity = 87%, positive predictive value = 96%, negative predictive value = 65% and accuracy = 85.2%. The positive likelihood ratio was 6.68 and the negative likelihood ratio 0.17. When our results were confronted with a metanalysis 99m-Tc sestamibi at rest (our results being firstly showed), sensitivity was 85% vs. 81%, specificity 87% vs. 60%, respectively. In relation to literature data for 201-Thallium were 85% vs. 90% e 87% vs. 54%, for sensitivity, specificity, respectively. In conclusion, 99m-Tc sestamibi-low dose dobutamine seems to be a promising test to detect viability, superior to that modality of rest perfusion, with predictive values comparable to the available literature for this methodology: 85,2% vs. 87%, 96% vs. 90% e 65% vs. 83%, results for accuracy, positive predictive value and negative predictive value, respectively. | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | por | pt_BR |
dc.rights | Open Access | en |
dc.subject | Isquemia miocárdica | pt_BR |
dc.subject | Miocárdio | pt_BR |
dc.subject | Ecocardiografia | pt_BR |
dc.subject | Cintilografia | pt_BR |
dc.subject | Tecnécio Tc 99m Sestamibi | pt_BR |
dc.subject | Dobutamina | pt_BR |
dc.subject | Tálio | pt_BR |
dc.subject | Estudo comparativo | pt_BR |
dc.title | Estudo comparativo da viabilidade miocárdica em áreas dissinérgicas ao ecocardiograma basal : cintilografia tomográfica com Tecnécio 99m-mibi sob baixa dose de Dobutamina versus Tálio em repouso-redistribuição | pt_BR |
dc.type | Dissertação | pt_BR |
dc.identifier.nrb | 000314785 | pt_BR |
dc.degree.grantor | Universidade Federal do Rio Grande do Sul | pt_BR |
dc.degree.department | Faculdade de Medicina | pt_BR |
dc.degree.program | Programa de Pós-Graduação em Ciências da Saúde: Cardiologia e Ciências Cardiovasculares | pt_BR |
dc.degree.local | Porto Alegre, BR-RS | pt_BR |
dc.degree.date | 2000 | pt_BR |
dc.degree.level | mestrado | pt_BR |
Ficheros en el ítem
Este ítem está licenciado en la Creative Commons License
-
Ciencias de la Salud (9041)