Mostrar registro simples

dc.contributor.authorAlmeida Júnior, Gustavo Luiz Gouvêa dept_BR
dc.contributor.authorClausell, Nadine Oliveirapt_BR
dc.contributor.authorGarcia, Marcelo Ióriopt_BR
dc.contributor.authorEsporcatte, Robertopt_BR
dc.contributor.authorRangel, Fernando Oswaldo Diaspt_BR
dc.contributor.authorRocha, Ricardo Mourilhept_BR
dc.contributor.authorSilva Neto, Luís Beck dapt_BR
dc.contributor.authorSilva, Fabrício Braga dapt_BR
dc.contributor.authorGorgulho, Paula de Castro Carvalhopt_BR
dc.contributor.authorXavier, Sérgio Sallespt_BR
dc.date.accessioned2019-10-10T03:49:47Zpt_BR
dc.date.issued2018pt_BR
dc.identifier.issn0066-782Xpt_BR
dc.identifier.urihttp://hdl.handle.net/10183/200372pt_BR
dc.description.abstractFundamento: Exame físico e peptídeo natriurético do tipo B (BNP) foram usados para estimar a hemodinâmica e adequar a terapia de pacientes com insuficiência cardíaca aguda descompensada (ICAD). Entretanto, correlação entre esses parâmetros e a pressão de enchimento do ventrículo esquerdo é controversa. Objetivo: Avaliar a acurácia diagnóstica do exame físico, da radiografia de tórax (RT) e do BNP para estimar a pressão atrial esquerda (PAE) avaliada pelo ecodopplercardiograma tecidual. Métodos: Pacientes admitidos com ICAD foram avaliados prospectivamente. As características diagnósticas dos sinais físicos de insuficiência cardíaca, RT e BNP para predizer elevação da PAE (> 15 mmHg), isolados ou combinados, foram calculadas. Teste de Spearman foi usado para analisar a correlação entre variáveis de distribuição não normal. O nível de significância foi 5%. Resultados: Este estudo incluiu 43 pacientes com idade média de 69,9 ± 11,1 anos, fração de ejeção ventricular esquerda de 25 ± 8.0%, e BNP de 1057 ± 1024,21 pg/mL. Individualmente, todos os parâmetros clínicos, RT e BNP apresentaram fraco desempenho para predizer PAE ≥ 15 mmHg. O escore clínico de congestão teve o pior desempenho [área sob a curva receiver operating characteristic (AUC) 0,53], seguindo-se escore clínico + RT (AUC 0,60), escore clínico + RT + BNP > 400 pg/mL (AUC 0,62) e escore clínico + RT + BNP > 1000 pg/mL (AUC 0,66). Conclusão: Exame físico, RT e BNP tiveram desempenho fraco para predizer PAE ≥15 mmHg. O uso desses parâmetros isoladamente ou em combinação pode levar a estimativa imprecisa do perfil hemodinâmico.pt_BR
dc.description.abstractBackground: Physical examination and B-type natriuretic peptide (BNP) have been used to estimate hemodynamics and tailor therapy of acute decompensated heart failure (ADHF) patients. However, correlation between these parameters and left ventricular filling pressures is controversial. Objective: This study was designed to evaluate the diagnostic accuracy of physical examination, chest radiography (CR) and BNP in estimating left atrial pressure (LAP) as assessed by tissue Doppler echocardiogram. Methods: Patients admitted with ADHF were prospectively assessed. Diagnostic characteristics of physical signs of heart failure, CR and BNP in predicting elevation (> 15 mm Hg) of LAP, alone or combined, were calculated. Spearman test was used to analyze the correlation between non-normal distribution variables. The level of significance was 5%. Results: Forty-three patients were included, with mean age of 69.9 ± 11.1years, left ventricular ejection fraction of 25 ± 8.0%, and BNP of 1057 ± 1024.21 pg/mL. Individually, all clinical, CR or BNP parameters had a poor performance in predicting LAP ≥ 15 mm Hg. A clinical score of congestion had the poorest performance [area under the receiver operating characteristic curve (AUC) 0.53], followed by clinical score + CR (AUC 0.60), clinical score + CR + BNP > 400 pg/mL (AUC 0.62), and clinical score + CR + BNP > 1000 pg/mL (AUC 0.66). Conclusion: Physical examination, CR and BNP had a poor performance in predicting a LAP ≥15 mm Hg. Using these parameters alone or in combination may lead to inaccurate estimation of hemodynamics.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.relation.ispartofArquivos brasileiros de cardiologia. São Paulo. Vol. 110, n. 3, (2018), p. 270-277.pt_BR
dc.rightsOpen Accessen
dc.subjectInsuficiência cardíacapt_BR
dc.subjectHeart failureen
dc.subjectNatriuretic peptide, brainen
dc.subjectHemodinâmicapt_BR
dc.subjectHemodynamicsen
dc.subjectFuncao ventricular esquerdapt_BR
dc.subjectEcocardiografia dopplerpt_BR
dc.subjectVentricular function, leften
dc.subjectEchocardiography, Doppleren
dc.subjectPeptídeo natriurético encefálicopt_BR
dc.titlePeptídeo natriurérico e avaliação clínica no diagnóstico do perfil hemodinâmico da insuficiencia cardíaca : comparação com ecodopplercardiograma tecidualpt_BR
dc.title.alternativeNatriuretic peptide and clinical evaluation in the diagnosis of heart failure hermodynamic profile : comparison with tissue Doppler echocardiographyen
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb001102594pt_BR
dc.type.originNacionalpt_BR


Thumbnail
Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples