Show simple item record

dc.contributor.advisorBianchin, Marino Muxfeldtpt_BR
dc.contributor.authorFranz, Karina Niquept_BR
dc.date.accessioned2019-05-16T02:37:05Zpt_BR
dc.date.issued2013pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/194282pt_BR
dc.description.abstractNeste trabalho foi desenvolvido uma modelo físico experimental para simulação de imagens de fase ictal em eplepsia. O simulador é composto de um tanque de dimensões 40x30x30 cm³, preenchido com o volume de 15l de água destilada (H2O2) e 11,72mCi de pertecnetato de sódio (Na99mTcO4). Dois eletrodos metálicos foram inseridos presos a um suporte de acrílico. Imagens dinâmicas e de SPECT/CT foram realizadas no sistema basal. Para simulação de fase ictal, os eletrodos foram ligados a uma fonte de alimentação de 57,4 V. As imagens de SPECT/CT e imagens dinâmicas foram realizadas durante a aplicação de campo elétrico. Ao cessar o campo, imagens dinâmicas do processo de difusão também foram adquiridas. As imagens foram analisadas visualmente, onde uma área de hipercaptação é percebida durante aplicação de campo elétrico. Os histogramas e perfis de contagem foram traçados, e calculado o FWHM cujos valores obtidos foram: 18,98; 16,82 e 17,35 para as imagens sem campo, com campo e difusão, respectivamente. Para imagens tomográficas os valores de FWHM encontrados foram: 2,12 para imagens sem campo e 1,32 para imagens com campo elétrico aplicado. Nos perfis de contagem, as imagens sem campo apresentam uma distribuição mais homogênea, quando comparada com a distribuição com campo elétrico e de difusão. Estudos futuros serão realizados para avaliar a relação entre diferença de potencial aplicado e o valor das contagens, assim como a abordagem do simulador em sistemas mais complexos, como o phantom para cérebro Hoffman 3D.pt
dc.description.abstractThe present work was put forth to evaluate the detectability of a epileptogenic zone in a physical model in cerebral SPECT studies. It has been developed an experimental physical model to simulate imaging of the ictal stage in epilepsy. The simulator is composed of a tank wiht dimensions of 40x30x30 cm³, filled with 15 liters of distilled water (H2O2) and 11,72mCi of sodium pertecnetate (Na99mTcO4). Two metallical electrodes were inserted, binded to an acrylic bracket. Dynamic and SPECT/CT images were made in the basal system. For the purpose of simulating an ictal stage, the electrodes were connected to a 57,4V power source. The SPECT/CT and dynamic images were made during the application of an electric field. Ceasing the application of the field, dynamic images of the diffusion process were also acquired. The images were visually analyzed, and an area of hypercaptation is seen during the application of the electric field. The histograms and counting profiles were obtained, the FWHM was calculated, whose values are: 18,98, ; 16,82 e 17,35 for the fieldless, field on and diffusion images, respectively. For the tomographical images the FWHM values found were: 2,12 for fieldless images and 1,32 with electric field. In the counting profiles, the fieldless images present a more homogeneous distribution, when compared with the electric and diffusion distributions. Future studies will be implemented to evaluate the relation between the difference of applied potential and counting level, as the approach of the simulator in more complex systems will be studied, like the Hoffman 3D brain phantom.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectTomografia computadorizada de emissão de fóton únicopt_BR
dc.subjectCérebropt_BR
dc.subjectMedicina nuclearpt_BR
dc.subjectEpilepsiapt_BR
dc.titleDetectabilidade de zona epileptogênica em modelo físico para spect cerebralpt_BR
dc.typeDissertaçãopt_BR
dc.identifier.nrb000897989pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Medicinapt_BR
dc.degree.programPrograma de Pós-Graduação em Medicina: Ciências Médicaspt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2013pt_BR
dc.degree.levelmestradopt_BR


Files in this item

Thumbnail
   

This item is licensed under a Creative Commons License

Show simple item record