dc.description.abstractObjetivo: O objetivo desse estudo foi comparar a latência e amplitude do potencial evocado auditivo cortical P1i entre neonatos em estado de alerta e durante o sono leve. Métodos: Vinte e cinco neonatos com emissões otoacústicas evocadas transientes presentes foram testados, por meio do potencial evocado auditivo cortical (PEAC), sendo dez em estado de alerta e 15 durante o sono leve. Para pesquisa dos potenciais corticais, utilizou-se o equipamento Hearlab System, de um canal, no módulo Cortical Tone Evaluation (CTE). O potencial P1i foi pesquisado de forma monoaural, na intensidade de 80 dBnNA, para as frequências de 500, 1000, 2000 e 4000Hz. A detecção do P1i foi feita de maneira automática pelo equipamento. A marcação da latência e amplitude foi realizada por três juízes. Resultados: Não houve diferença estatisticamente significativa entre os dois grupos de neonatos para os valores de amplitude e latência, nas quatro frequências testadas. Conclusão: Não houve influência do estado comportamental dos neonatos na avaliação do potencial cortical P1i.pt
dc.description.abstractPurpose: The aim of the present study was to compare latency and amplitude of the cortical auditory evoked response P1i among newborns in an alert state and during light sleep. Methods: Twenty-five neonates with normal transient evoked otoacoustic emissions were tested with cortical auditory evoked potentials (CAEP): 10 were in an alert state and 15 in light sleep during testing. For the investigation of cortical potentials, a single-channel Hearlab System equipment, Cortical Tone Evaluation module (CTE), was used. The P1i potential was investigated monoaurally at an 80dBnHL intensity at 500, 1000, 2000 and 4000 Hz. P1i was automatically detected by the equipment. Latency and amplitude were marked by three judges. The responses of the newborn in an alert state were compared with those in light sleep. Results: There was no statistically significant difference between the two groups of neonates for the amplitude and latency values at the four tested frequencies. Conclusion: There was no influence of the neonates’ behavioral state on the evaluation of the P1i auditory cortical potential.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.relation.ispartofAudiology - Communication Research. São Paulo. Vol. 23 (2018), e1987, 6 p.pt_BR
dc.rightsOpen Accessen
dc.subjectPotenciais evocados auditivospt_BR
dc.subjectEvoked potentials, auditoryen
dc.subjectSleepen
dc.subjectRecém-nascidopt_BR
dc.subjectEletrofisiologiapt_BR
dc.subjectHearingen
dc.subjectInfant, newbornen
dc.subjectSonopt_BR
dc.subjectElectrophysiologyen
dc.titleEfeito do estado atencional na detecção automática das respostas auditivas corticais em neonatospt_BR