Estudo do atrito lateral no arrancamento de estacas modelo instaladas por fluidização em areia
dc.contributor.advisor | Schnaid, Fernando | pt_BR |
dc.contributor.author | Mazutti, Júlia Hein | pt_BR |
dc.date.accessioned | 2018-10-02T02:35:00Z | pt_BR |
dc.date.issued | 2018 | pt_BR |
dc.identifier.uri | http://hdl.handle.net/10183/183019 | pt_BR |
dc.description.abstract | O objetivo desta dissertação consiste em aprofundar o entendimento dos mecanismos que controlam o atrito lateral sob arrancamento de estacas instaladas por fluidização em areia. A técnica de instalação é estudada como uma alternativa para a utilização de estacas torpedo na fixação de plataformas offshore. Trabalhou-se em laboratório com o arrancamento de estacas metálicas circulares em modelo reduzido. Foram utilizados três diâmetros de estacas modelo, simulando três diferentes escalas: 14 mm (1:76), 16,2 mm (1:67) e 21,3 mm (1:50). Foram realizados 8 ensaios de arrancamento (24 horas após a fluidização) em estacas modelo instaladas por fluidização em solo arenoso com densidade relativa de 50% e submetido à sobrecarga de 2,236 kPa. Foram também realizados 17 ensaios de arrancamento em estacas modelo pré-instaladas (sem fluidização) em areia com densidade relativa de 30%, simulando uma instalação sem perturbação do solo, uma vez que esta é a densidade relativa aproximada que a areia atinge após o processo de fluidização. Os resultados foram comparados com pesquisas anteriores de arrancamento de estacas instaladas por fluidização em areia. Para um aumento médio de 2 vezes a tensão vertical efetiva nas estacas modelo instaladas por fluidização com sobrecarga, observa-se um ganho médio de 1,8 na resistência. O coeficiente de empuxo lateral de serviço 𝐾𝑠 para estes ensaios não apresentou diferenças significativas em relação ao mesmo tipo de ensaio sem sobrecarga. As estacas instaladas por fluidização com sobrecarga e estacas pré-instaladas (sem perturbação) apresentam valores de 𝐾𝑠 constantes e independentes das profundidades instaladas, com respectivas médias de 0,15 e 0,31. O valor de 𝐾𝑠 parece aumentar com o tempo para as estacas fluidizadas (efeito setup) devido à reconstituição das tensões radiais. Os valores 𝐾𝑠 de estacas cravadas em areia densa diminuem seu valor com o aumento da profundidade instalada (e da tensão efetiva média atuante), por restrição de dilatação, tendendo ao valor de 𝐾𝑠 encontrado para ensaios pré-instalados realizados neste trabalho. | pt |
dc.description.abstract | The main goal of this study is to deepen the understanding of the shaft friction behavior under tension loads of piles installed by fluidization in Osório sand. The installation technique is studied as an alternative for the use of torpedo piles in offshore platforms anchoring. This work was done in laboratory with metallic circular piles in reduced model. Three diameters of model piles were used, simulating three different scales: 14 mm (1:76), 16,2 mm (1:67) and 21,3 mm (1:50). Eight pullout tests (24 hours after fluidization) were carried out on model piles installed by fluidization in sandy soil with a relative density of 50% and subjected to a surcharge of 2,236 kPa. Eighteen pullout tests were performed on pre-installed (non-fluidized) model piles in sand with a relative density of 30%, simulating an installation without soil disturbance, since this is the approximate relative density reached after the process of fluidization. The results were compared with previous studies of pullout resistance of fluidized piles in sand. For an average increase of 2 times the vertical effective stress in the model piles installed by fluidization with surcharge, an average increase of 1,8 times is observed in the pullout resistance. The lateral earth pressure coefficient on the pile shaft 𝐾𝑠 for these tests did not show significant differences in relation to the same type of test without surcharge. For tests installed by fluidization and pre-installed tests (without soil disturbance), 𝐾𝑠 remains constant and independent of the installed depths, with respective averages of 0,15 and 0,31. The 𝐾𝑠 value seems to increase with time for fluidized tests (setup effect) due to the reconstitution of the radial tensions. The 𝐾𝑠 values for pullout tests in driven model piles in dense sand decrease their value with the increase of the installed depth (and the increase of the vertical effective stress), by restriction of the expansive behavior, tending to the 𝐾𝑠 value found for pre-installed tests carried out in this work. | en |
dc.format.mimetype | application/pdf | pt_BR |
dc.language.iso | por | pt_BR |
dc.rights | Open Access | en |
dc.subject | Fluidization | en |
dc.subject | Estaca torpedo | pt_BR |
dc.subject | Prova de carga | pt_BR |
dc.subject | Lateral earth pressure coefficient on the pile shaft | en |
dc.subject | Setup effect | en |
dc.subject | Areia | pt_BR |
dc.subject | Shaft friction | en |
dc.subject | Osório sand | en |
dc.subject | Surcharge | en |
dc.subject | Torpedo piles | en |
dc.title | Estudo do atrito lateral no arrancamento de estacas modelo instaladas por fluidização em areia | pt_BR |
dc.type | Dissertação | pt_BR |
dc.contributor.advisor-co | Festugato, Lucas | pt_BR |
dc.identifier.nrb | 001077011 | pt_BR |
dc.degree.grantor | Universidade Federal do Rio Grande do Sul | pt_BR |
dc.degree.department | Escola de Engenharia | pt_BR |
dc.degree.program | Programa de Pós-Graduação em Engenharia Civil | pt_BR |
dc.degree.local | Porto Alegre, BR-RS | pt_BR |
dc.degree.date | 2018 | pt_BR |
dc.degree.level | mestrado | pt_BR |
Este item está licenciado na Creative Commons License
-
Engenharias (7440)Engenharia Civil (1185)