Mostrar el registro sencillo del ítem
Which mode and potency of electrocoagulation yields the smallest unobstructed area of the Fallopian tubes?
dc.contributor.author | Campagnolo, Marcelo Ivo | pt_BR |
dc.contributor.author | Reis, Ricardo dos | pt_BR |
dc.contributor.author | Santos, Marcele Oliveira dos | pt_BR |
dc.contributor.author | Kliemann, Lucia Maria | pt_BR |
dc.contributor.author | Savaris, Ricardo Francalacci | pt_BR |
dc.date.accessioned | 2018-07-31T02:33:43Z | pt_BR |
dc.date.issued | 2018 | pt_BR |
dc.identifier.issn | 0100-7203 | pt_BR |
dc.identifier.uri | http://hdl.handle.net/10183/180852 | pt_BR |
dc.description.abstract | Objective To determine which mode and potency of electrocoagulation, using a modern electrosurgical generator, yields the smallest unobstructed area of the Fallopian tubes. Methods In an experimental study, tubes from 48 hysterectomies or tubal ligation were evaluated. Tubes were randomly allocated to one of the following groups: group A) 25 W x 5 seconds (n ¼ 17); group B) 30 W x 5 seconds (n ¼ 17); group C) 35 W x 5 seconds (n ¼ 18), group D) 40 W x 5 seconds (n ¼ 20); group E) 40 W x 5 seconds with visual inspection (blanch, swells, collapse) (n ¼ 16); group F) 50 W x 5 seconds (n ¼ 8). Bipolar electrocoagulation was performed in groups A to E, and monopolar electrocoagulation was performed in group F. Coagulation mode was used in all groups. Digital photomicrography of the transversal histological sections of the isthmic segment of the Fallopian tube were taken, and themedian percentage of unobstructed luminal area (mm2) was measured with ImageJ software (ImageJ, National Institutes of Health, Bethesda, MD, USA). The Kruskal-Wallis test or analysis of variance (ANOVA) was used for statistical analysis. Results Ninety-six Fallopian tube sections were analyzed. The smallest median occluded area (%; range) of the Fallopian tube was obtained in the group with 40 W with visual inspection (8.3%; 0.9–40%), followed by the groups 25 W (9.1%; 0–35.9%), 40 W (14.2; 0.9–43.2%), 30 W (14.2; 0.9–49.7%), 35 W (15.1; 3–46.4%) and 50 W (38.2; 3.1–51%). No statistically significant difference was found among groups (p ¼ 0.09, Kruskal-Wallis test). | en |
dc.format.mimetype | application/pdf | pt_BR |
dc.language.iso | eng | pt_BR |
dc.relation.ispartof | Revista brasileira de ginecologia & obstetrícia. Rio de Janeiro. Vol. 40, n. 6 (2018), p. 332-337 | pt_BR |
dc.rights | Open Access | en |
dc.subject | Tubal ligation | en |
dc.subject | Ligadura | pt_BR |
dc.subject | Fulguration | en |
dc.subject | Eletrocoagulação | pt_BR |
dc.subject | Tubas uterinas | pt_BR |
dc.subject | Occlusion | en |
dc.title | Which mode and potency of electrocoagulation yields the smallest unobstructed area of the Fallopian tubes? | pt_BR |
dc.title.alternative | Qual modo e potência produzem a menor área de nãoobstrução nas tubas de Falópio? | pt |
dc.type | Artigo de periódico | pt_BR |
dc.identifier.nrb | 001072448 | pt_BR |
dc.type.origin | Nacional | pt_BR |
Ficheros en el ítem
Este ítem está licenciado en la Creative Commons License
-
Artículos de Periódicos (40281)Ciencias de la Salud (10760)