Correlação entre a variabilidade da pressão arterial de muito curto prazo e curto prazo em indivíduos diabéticos-hipertensos e saudáveis
dc.contributor.author | Casali, Karina Rabello | pt_BR |
dc.contributor.author | Schaan, Beatriz D'Agord | pt_BR |
dc.contributor.author | Montano, Nicola | pt_BR |
dc.contributor.author | Massierer, Daniela | pt_BR |
dc.contributor.author | Freitas Neto, Flávio Maciel de | pt_BR |
dc.contributor.author | Teló, Gabriela Heiden | pt_BR |
dc.contributor.author | Ledur, Priscila dos Santos | pt_BR |
dc.contributor.author | Reinheimer, Marília | pt_BR |
dc.contributor.author | Sbruzzi, Graciele | pt_BR |
dc.contributor.author | Gus, Miguel | pt_BR |
dc.date.accessioned | 2018-07-04T02:26:40Z | pt_BR |
dc.date.issued | 2018 | pt_BR |
dc.identifier.issn | 0066-782X | pt_BR |
dc.identifier.uri | http://hdl.handle.net/10183/180044 | pt_BR |
dc.description.abstract | Fundamento: A variabilidade da pressão arterial (PA) pode ser avaliada por meio da monitorização ambulatorial da PA em 24 horas (MAPA-24h), mas sua concordância com os resultados da medição da PA digital (MPAD) ainda não foi estabelecida. Objetivo: O objetivo deste estudo foi comparar os parâmetros da variabilidade a curto prazo (MAPA-24h) com a variabilidade da PA a muito curto prazo (MPAD) em sujeitos saudáveis (C) e diabéticos-hipertensos (DH). Métodos: Estudo transversal com 51 sujeitos DH e 12 sujeitos C que se submeteram a MAPA-24h [extraindo time rate, desvio padrão (SD) e coeficiente de variação (CV)] e registro batimento-a-batimento em repouso e após manobra de manobra de ortostatismo ativo [MPAD, extraindo parâmetros de variabilidade da PA e da frequência cardíaca (FC) no domínio da frequência, análise espectral por modelagem autoregressiva]. O coeficiente de correlação de postos de Spearman foi utilizado para correlacionar os parâmetros de variabilidade de PA e FC obtidos tanto da MPAD quanto da MAPA-24h (dividida em dia, noite e total). A significância estatística foi estabelecida em p < 0.05. Resultados: Houve uma variação circadiana dos níveis de PA nos grupos C e DH; A PA sistólica e a taxa de tempo foram maiores em indivíduos DH em todos os períodos avaliados. Em indivíduos C, foram apresentadas altas correlações positivas entre o índice de taxa de tempo (MAPA-24h) e o componente de baixa frequência (LF, do inglês low frequency) da variabilidade de curto prazo (MPAD, total, R = 0,591, p = 0,043); desvio padrão (MAPA-24h) com o componente de LF VPA (MPAD, total, R = 0,608, p = 0,036), coeficiente de variação (24h-ABPM) com VPA total (MPAD, dia, -0,585, p = 0,046) e índice alfa (MPAD, dia, -0,592, p = 0,043), taxa de tempo (MAPA-24h) e delta LF/HF (MPAD, total, R = 0,636, p = 0,026; dia R = 0,857, p < 0,001). Os registros obtidos dos pacientes DH apresentaram correlações positivas fracas. Conclusões: Os índices obtidos a partir da MAPA-24h (total, durante o dia) refletem a variabilidade da PA e da FC avaliada pela MPAD em indivíduos saudáveis, o que não se aplica a indivíduos DH. (Arq Bras Cardiol. 2018; 110(2):157-165) | pt_BR |
dc.description.abstract | Background: Blood pressure (BP) variability can be evaluated by 24-hour ambulatory BP monitoring (24h-ABPM), but its concordance with results from finger BP measurement (FBPM) has not been established yet. Objective: The aim of this study was to compare parameters of short-term (24h-ABPM) with very short-term BP variability (FBPM) in healthy (C) and diabetic-hypertensive (DH) subjects. Methods: Cross-sectional study with 51 DH subjects and 12 C subjects who underwent 24h-ABPM [extracting time-rate, standard deviation (SD), coefficient of variation (CV)] and short-term beat-to-beat recording at rest and after standing-up maneuvers [FBPM, extracting BP and heart rate (HR) variability parameters in the frequency domain, autoregressive spectral analysis]. Spearman correlation coefficient was used to correlate BP and HR variability parameters obtained from both FBPM and 24h-ABPM (divided into daytime, nighttime, and total). Statistical significance was set at p < 0.05. Results: There was a circadian variation of BP levels in C and DH groups; systolic BP and time-rate were higher in DH subjects in all periods evaluated. In C subjects, high positive correlations were shown between time-rate index (24h-ABPM) and LF component of short-term variability (FBPM, total, R = 0.591, p = 0.043); standard deviation (24h-ABPM) with LF component BPV (FBPM, total, R = 0.608, p = 0.036), coefficient of variation (24h-ABPM) with total BPV (FBPM, daytime, -0.585, p = 0.046) and alpha index (FBPM, daytime, -0.592, p = 0.043), time rate (24h-ABPM) and delta LF/HF (FBPM, total, R = 0.636, p = 0.026; daytime R = 0,857, p < 0.001). Records obtained from DH showed weak positive correlations. Conclusions: Indices obtained from 24h-ABPM (total, daytime) reflect BP and HR variability evaluated by FBPM in healthy individuals. This does not apply for DH subjects. (Arq Bras Cardiol. 2018; 110(2):157-165) | en |
dc.format.mimetype | application/pdf | pt_BR |
dc.language.iso | por | pt_BR |
dc.relation.ispartof | Arquivos brasileiros de cardiologia. São Paulo. Vol. 110, n.2 (fev. 2018), p. 157-165 | pt_BR |
dc.rights | Open Access | en |
dc.subject | Hipertensão | pt_BR |
dc.subject | Hypertension | en |
dc.subject | Diabetes mellitus | en |
dc.subject | Diabetes mellitus tipo 2 | pt_BR |
dc.subject | Type 2 | en |
dc.subject | Sistema nervoso autônomo | pt_BR |
dc.subject | Autonomic nervous system | en |
dc.subject | Monitorização ambulatorial da pressão arterial | pt_BR |
dc.subject | Blood pressure monitoring | en |
dc.subject | Ambulatory | en |
dc.title | Correlação entre a variabilidade da pressão arterial de muito curto prazo e curto prazo em indivíduos diabéticos-hipertensos e saudáveis | pt_BR |
dc.title.alternative | Correlation between very short and short-term blood pressure variability in diabetic-hypertensive and healthy subjects | en |
dc.type | Artigo de periódico | pt_BR |
dc.identifier.nrb | 001069724 | pt_BR |
dc.type.origin | Nacional | pt_BR |
Este item está licenciado na Creative Commons License
-