Mostrar registro simples

dc.contributor.advisorHammes, Luciano Serpapt_BR
dc.contributor.authorGuterres, Cátia Moreirapt_BR
dc.date.accessioned2018-04-17T02:27:44Zpt_BR
dc.date.issued2017pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/174768pt_BR
dc.description.abstractIntrodução: O câncer de colo uterino é o quarto câncer mais comum no sexo feminino e um importante problema mundial de saúde pública. Recentemente, o uso de biomarcadores para melhorar a sensibilidade e especificidade do rastreamento e diagnóstico desta patologia passou a ter maior importância. Dentre estes, P16 e Ki67 passaram a ser largamente utilizados em imunohistoquímica de amostras preservadas em parafina. Entretanto, não se sabe qual a influência do tempo e temperatura de armazenamento de amostras previamente cortadas. Objetivo: O presente estudo tem por finalidade avaliar a influência do tempo de preparo e temperatura de armazenamento na imunorreatividade para P16 e Ki67 de cortes de amostras cervicais. Métodos: Amostras de blocos de parafina de câncer de colo uterino foram seccionadas e montadas em lâminas, de maneira seriada, no período de 9, 6, 3, 1 mês e tempo zero, sendo armazenadas em -20°C, 4°C e temperatura ambiente (TA). Todas as amostras então foram processadas ao mesmo tempo por imunohistoquímica para detecção de P16 e Ki67, sendo realizada leitura da mesma região do tumor nas diferentes condições. Resultados: Dos 10 casos de câncer de colo uterino, foram analisadas 75 regiões para P16 e Ki67 nas diferentes condições. A expressão de P16 e Ki67 não variou de maneira significativa ao longo do tempo nas diferentes condições de temperatura de armazenamento. Por exemplo, os cortes de 9 meses apresentaram a seguinte expressão quando armazenados a -20°C, 4°C e TA, respectivamente [mediana (p25-75)]: marcador P16 - 200 (160-300), 200 (180-300) e 200 (170-300), o que não foi estatisticamente diferente do corte em tempo zero, 200 (200-300), P=0,210; marcador Ki 67 - 210 (160-270), 210 (160-270) e 210 (145-270), o que também não foi estatisticamente diferente do corte em tempo zero, 240 (180-270), P=0,651. Conclusão: Não há influência significativa do tempo de preparo e temperatura de armazenamento de lâminas com material já cortado para a realização de imunohistoquímica posteriormente, no período de até 9 meses, para P16 e Ki67. Isto permite que, ao processarmos lâminas para HE e/ou outros marcadores, podemos reservar lâminas para posterior processamento com P16 e Ki67 sem prejuízo à imunorreatividade.pt_BR
dc.description.abstractIntroduction: Cervical cancer is the fourth most common cancer in women and a major public health problem in the world. Recently, the use of biomarkers to improve the sensitivity and specificity of the screening and diagnosis of this pathology has become more important. Among these, P16 and Ki67 became widely used in immunohistochemistry of samples preserved in paraffin. However, the influence of storage time and temperature of previously cut samples is not known. Aim: The aim of this study was to evaluate the influence of preparation time and storage temperature on the immunoreactivity for P16 and Ki67 of cervical specimens. Methods: Cervical cancer paraffin blocks were sectioned and mounted onto glass slides in 9, 6, 3, 1 month and zero time and stored at -20°C, 4°C and room temperature (RT). All slides were then processed at the same time by immunohistochemistry for the detection of P16 and Ki67, and the same tumor region was read under the different conditions. Results: Of the 10 cases of cervical cancer, 75 regions were analyzed for P16 and Ki67 under different conditions. Expression of P16 and Ki67 did not vary significantly over time at different storage temperature conditions. For example, the 9-month slides showed the following expression when stored at -20°C, 4°C and RT, respectively [median (p25-75)]: P16 - 200 (160-300), 200 (180-300) and 200 (170-300), which was not statistically different from zero time cut, 200 (200-300), P = 0.210; Ki 67 - 270 (160-270), 210 (160-270) and 210 (145-270), which was also not statistically different from zero-time cutoff, 240 (180-270), P = 0.651. Conclusion: There is no significant influence of the preparation time and storage temperature of slides of cervical cancer to be processed by immunohistochemistry later, in the period of up to 9 months, for P16 and Ki67. This allows, when processing slides for HE and / or other markers, we can reserve slides for further processing with P16 and Ki67 without impairing immunoreactivity.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectImmunohistochemistryen
dc.subjectImuno-histoquímicapt_BR
dc.subjectNeoplasias do colo do úteropt_BR
dc.subjectKi67en
dc.subjectP16en
dc.subjectPapillomaviridaept_BR
dc.subjectPreservação de amostras de águapt_BR
dc.subjectBiomarkers of cervical neoplasiaen
dc.subjectBiomarcadores tumoraispt_BR
dc.subjectAging of bladesen
dc.subjectColoração e rotulagempt_BR
dc.titleEstudo da influência do tempo de preparo e temperatura de armazenamento na imunorreatividade de amostras de câncer de colo uterinopt_BR
dc.typeDissertaçãopt_BR
dc.identifier.nrb001064341pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Medicinapt_BR
dc.degree.programPrograma de Pós-Graduação em Ciências da Saúde: Ginecologia e Obstetríciapt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2017pt_BR
dc.degree.levelmestradopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples