dc.description.abstractO biodiesel vem se consolidando como combustível alternativo devido às suas vantagens e importância econômica. Conforme seu percentual no diesel comercial cresce, o monitoramento da qualidade se torna cada vez mais importante para uma comercialização segura. No entanto, a estabilidade oxidativa do biodiesel é inferior à do diesel fóssil, assim antioxidantes sintéticos, tais como BHA, BHT, PG e TBHQ, são adicionados para prevenir a degradação do mesmo, evitando danos ao sistema de combustão automotivo. Os métodos para avaliar a estabilidade oxidativa e a quantidade de antioxidantes são em geral demorados, requerem preparação amostral ou equipamentos de alto custo. Com o objetivo de contornar tais problemas, neste trabalho foi aplicada uma metodologia para análise direta de antioxidantes em amostras de biodiesel por meio de voltametria de pulso diferencial. Conjuntamente, foi estudada a viabilidade da associação dessa metodologia com técnicas quimiométricas para a determinação simultânea desses antioxidantes em misturas de antioxidantes em biodiesel. Para permitir uma análise direta, sem extração e pré-concentração dos analitos, o biodiesel foi diluído em meio etanólico. Medidas de voltametria de pulso diferencial para cada antioxidante individualmente mostraram relação linear entre as concentrações dos antioxidantes e a corrente de oxidação. Os limites de detecção individuais obtidos foram de 20,5 mg L-1 para BHA, 32,4 mg L-1 para BHT, 35,5 mg L-1 para PG e 26,5 mg L-1 para TBHQ. A modelagem quimiométrica foi aplicada por meio das ferramentas Mínimos Quadrados Clássico (CLS), Mínimos Quadrados Parciais (PLS), Redes Neuronais Artificiais (ANN), Componentes Principais-Redes Neuronais Artificiais (PC-ANN) e Árvore de Decisão-Redes Neuronais Artificiais (DT-ANN). O modelo construído por PLS se mostrou melhor quando comparado à modelagem por CLS. O modelo construído por ANN’s sem seleção de dados de entrada apresentou erros semelhantes ao PLS. Quando a redução da quantidade de dados de entrada foi aplicada em conjunto com ANN’s através de Análise por Componentes Principais (PCA) e DT, a aplicação de PCA levou a aumento de 10,2% no erro de predição, enquanto que na seleção por DT os erros de predição foram reduzidos em 8,5%. A determinação simultânea dos quatro compostos pelo modelo DT-ANN apresentou precisão satisfatória, com recuperação de 98% para BHA, 97% para BHT, 103% para PG e 100% para TBHQ, o que indica que a técnica analítica e a modelagem quimiométrica são viáveis e promissoras para aplicação no controle de qualidade do biodiesel, bem como em análises de monitoramento nas plantas industriais.pt_BR
dc.description.abstractBiodiesel is becoming established as an alternative fuel because its advantages and economic importance. As the levels of biodiesel in commercial diesel grows, quality monitoring becomes increasingly important for safe marketing. However, the oxidative stability of biodiesel is smaller than that of fossil diesel and synthetic antioxidants such as BHA, BHT, PG and TBHQ are added to it in order to prevent its degradation, avoiding damage to the automotive combustion system. Methods for evaluating oxidative stability and the amount of antioxidants are usually time-consuming, require sample preparation or expensive equipment. In order to overcome such problems, in this work a methodology was applied for direct analysis of antioxidants in biodiesel samples by means of differential pulse voltammetry. The viability of associating this methodology with chemometric techniques was studied for the simultaneous determination of these antioxidants in biodiesel. To allow a direct analysis, without extraction and preconcentration of analytes, biodiesel was diluted in ethanolic medium. Differential pulse voltammetric measurements for each antioxidant individually showed a linear relationship between antioxidant concentrations and oxidation current. The individual detection limits were 20,5 mg L-1 for BHA, 32,4 mg L-1 for BHT, 35,5 mg L-1 for PG and 26,5 mg L-1 for TBHQ. The chemometric modeling was applied using the Classical Least Squares (CLS), Partial Least Squares (PLS), Artificial Neural Networks (ANN), Principal Component-Artificial Neural Networks (PC-ANN) and Decision Tree-Artificial Neural Networks (DT-ANN) techniques. The model constructed by PLS was better than that obtained with CLS. The model constructed by ANN’s without input selection presented similar deviations in comparison to PLS. When amount of input data reduction was applied together with ANNs through Principal Component Analysis (PCA) and DT, the PCA application led to a 10.2% increase in prediction error, whereas in the selection by DT prediction errors were reduced by 8,5%. The simultaneous determination of the four compounds by the DT-ANN model presented satisfactory accuracy with 98% recovery for BHA, 97% for BHT, 103% for PG and 100% for TBHQ, indicating that the analytical technique and the chemometric modeling are feasible and promising for application in biodiesel quality control, as well as in monitoring analyzes in the industrial plants.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectANNen
dc.subjectBiodieselpt_BR
dc.subjectPLSen
dc.subjectVoltametriapt_BR
dc.subjectDifferential pulse voltammetryen
dc.subjectAntioxidantespt_BR
dc.subjectAntioxidantsen
dc.titleUso de voltametria de pulso diferencial combinada com quimiometria para determinação simultânea de antioxidantes em amostras de biodieselpt_BR
dc.typeDissertaçãopt_BR
dc.contributor.advisor-coFernandes, Pedro Rafael Bolognesept_BR
dc.identifier.nrb001061697pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentEscola de Engenhariapt_BR
dc.degree.programPrograma de Pós-Graduação em Engenharia Químicapt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2017pt_BR
dc.degree.levelmestradopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples