Manobra de hiperinsuflação com ventilador mecânico : uma revisão sistematica com metanálise
dc.contributor.advisor | Sbruzzi, Graciele | pt_BR |
dc.contributor.author | Saraiva, Mateus Sasso | pt_BR |
dc.date.accessioned | 2017-06-15T02:33:49Z | pt_BR |
dc.date.issued | 2017 | pt_BR |
dc.identifier.uri | http://hdl.handle.net/10183/159642 | pt_BR |
dc.description.abstract | Fundamento: A ventilação mecânica (VM) é um dos suportes de vida utilizados durante a internação em unidade de terapia intensiva. Entretanto, a alteração no mecanismo fisiológico de depuração mucociliar é um dos efeitos deletérios causados pela VM e pela prótese endotraqueal. Dessa forma, a fisioterapia respiratória objetiva manter as vias aéreas pérvias e as unidades alveolares expandidas, facilitando a ventilação pulmonar e para isso podem ser utilizadas manobras como hiperinsuflação manual (HM) ou hiperinsuflação com ventilador mecânico (HVM). Objetivo: Revisar sistematicamente os efeitos da HVM comparado com a HM no volume de secreção depurado, pneumonia associada à VM e tempo de VM em pacientes adultos em VM invasiva; e secundariamente, determinar os efeitos HVM nas variáveis respiratórias e hemodinâmicas. Métodos: Foi realizada uma busca sistemática nas bases de dados Cochrane CENTRAL, MEDLINE, Lilacs, PEDro e Embase, além de busca manual em referências de estudos publicados até agosto de 2016. Foram incluídos ensaios clínicos randomizados (ECRs) com pacientes adultos em VM que foram submetidos à manobra HVM comparando com manobra HM. Dois revisores independentes realizaram a seleção dos estudos, a extração dos dados e a avaliação da qualidade metodológica. Resultados: Do total de 3.949 artigos, três ECRs foram incluídos, totalizando 96 indivíduos. Foi observado que ambas as intervenções melhoram as variáveis respiratórias: volume de secreção (0,08g; IC95%: -0,70 a 0,85), complacência estática (1,01ml/cmH2O; IC95%: -5,80 a 7,83), complacência dinâmica (1,47 cmH2O; IC95%: - 3,43 a 6,36), relação PaO2/FiO2 (11,18; IC 95%: -26,28 a 48,65) e pressão arterial de dióxido de carbono (-0,38 mmHg; IC 95%: -2,78 a 2,03), sem diferença entre HVM e HM. Nenhum dos estudos incluídos avaliou as variáveis pneumonia associada à VM e tempo de VM. Conclusões: Esta revisão sistemática com metanálise, demonstrou que ambas as intervenções, melhoram os desfechos volume de secreção, complacência estática, complacência dinâmica, relação PaO2/FiO2 e pressão arterial de dióxido de carbono e que não existe diferença entre as mesmas, entretanto, devido as limitações dos estudos incluídos, novos estudos são necessários para confirmação dos achados. | pt_BR |
dc.description.abstract | Background: Mechanical ventilation (MV) is one of the supports used during intensive care unit admission. However, the change in the physiological mechanism of mucociliary clearance is one of the deleterious effects caused by MV and endotracheal prosthesis. Thus, respiratory physiotherapy aims to maintain the patent airways and expanded alveolar units, facilitating pulmonary ventilation and for this can be used maneuvers such as manual hyperinflation (HM) or hyperinflation with mechanical ventilator (HVM). Objective: To systematically review the effects of HVM compared with HM on the volume of depurated secretion, MV-associated pneumonia and MV time in adult patients in invasive MV; and secondarily to determine HVM effects on respiratory and hemodynamic variables. Methods: A systematic search was performed in the Cochrane CENTRAL, MEDLINE, Lilacs, PEDro and Embase databases, as well as a manual search in references of studies published up to August 2016. Randomized clinical trials (RCTs) were included, with adult patients in MV, that were submitted to the HVM maneuver comparing with HM maneuver. Two independent reviewers selected the studies, extracted data and assessed the methodological quality. Results: Of the total of 3,949 articles, three RCTs were included, totaling 96 individuals. It was observed that both interventions improved the respiratory variables: volume of secretion (0.08g, 95% CI: -0.70 to 0.85), static compliance (1.01ml / cmH2O, 95% CI: -5.80 to 7 , 83%), dynamic compliance (1.47 cmH2O, 95% CI: -3.43 to 6.36), PaO2 / FiO2 ratio (11.18; 95% CI: -26.28 to 48.65), and blood pressure Of carbon dioxide (-0.38 mmHg, 95% CI: -2.78 to 2.03), with no difference between HVM and HM. None of the included studies evaluated the variables pneumonia associated with MV and time of MV. Conclusions: This systematic review with meta-analysis has shown that both interventions improve the secretion volume, static compliance, dynamic compliance, PaO2 / FiO2 ratio and blood pressure of carbon dioxide and that there is no difference between them, however, due to limitations of the included studies, further studies are needed to confirm the findings. | en |
dc.format.mimetype | application/pdf | pt_BR |
dc.language.iso | por | pt_BR |
dc.rights | Open Access | en |
dc.subject | Ventiladores mecânicos | pt_BR |
dc.subject | Ventilators | en |
dc.subject | Mechanical | en |
dc.subject | Respiração artificial | pt_BR |
dc.subject | Modalidades de fisioterapia | pt_BR |
dc.subject | Respiration | en |
dc.subject | Artificial and pressure support ventilation | en |
dc.subject | Physiotherapy modalities | en |
dc.title | Manobra de hiperinsuflação com ventilador mecânico : uma revisão sistematica com metanálise | pt_BR |
dc.type | Dissertação | pt_BR |
dc.identifier.nrb | 001023884 | pt_BR |
dc.degree.grantor | Universidade Federal do Rio Grande do Sul | pt_BR |
dc.degree.department | Faculdade de Medicina | pt_BR |
dc.degree.program | Programa de Pós-Graduação em Ciências Pneumológicas | pt_BR |
dc.degree.local | Porto Alegre, BR-RS | pt_BR |
dc.degree.date | 2017 | pt_BR |
dc.degree.level | mestrado | pt_BR |
Files in this item
This item is licensed under a Creative Commons License
-
Health Sciences (9085)Pulmonology (501)