Mostrar registro simples

dc.contributor.advisorSilveiro, Sandra Pinhopt_BR
dc.contributor.authorSoares, Ariana Aguiarpt_BR
dc.date.accessioned2009-05-30T04:12:51Zpt_BR
dc.date.issued2008pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/15926pt_BR
dc.description.abstractIntrodução: As diretrizes de nefrologia recomendam a estimativa da taxa de filtração glomerular (TFG) para avaliar a função renal utilizando equações que incluam a creatinina sérica, como a desenvolvida no estudo MDRD. No entanto, existem controvérsias sobre a performance dessa equação nas faixas de normalidade da TFG e novas fórmulas têm sido propostas. Objetivo: Avaliar o desempenho das equações MDRD e Quadrática Clínica Mayo (QCM) para estimar a TFG comparando-as com a TFG medida por 51Cr-EDTA em adultos saudáveis. Pacientes e métodos: Estudo transversal. A TFG foi medida pela técnica do 51Cr-EDTA e estimada pelas fórmulas do MDRD e QCM. A creatinina sérica foi medida com método Jaffé compensado rastreável. Resultados: Foram avaliados 96 indivíduos, 61 mulheres (64%), 83 brancos (86%), com idade de 42±15 anos (19-86 anos). A TFG medida com 51Cr-EDTA (TFG51Cr) foi de 112±24, a TFGMDRD foi de 94±19 e a TFGQCM foi de 113±15 ml/min/1,73 m2. O viés (valor medido menos estimado) entre TFG51Cr e TFGMDRD foi de 18,3 ml/min/1,73 m2 , com limite de concordância (média±2 DP) de -34 a 70 ml/min/1,73 m2 . O viés entre TFG51Cr e TFGQCM foi de -1,4 ml/min/1,73 m2 (-51 a 49 ml/min/1,73 m2). A acurácia, calculada como a percentagem dos resultados estimados que desviam menos do que 15% do valor medido, foi de 40% para TFGMDRD e de 48% para TFGQCM. Conclusões: As fórmulas disponíveis para a estimativa da TFG não apresentam acurácia satisfatória para expressar o valor medido da variável na faixa de normalidade.pt_BR
dc.description.abstractBackground: Current guidelines recommend glomerular filtration rate (GFR) estimation to analyse renal function employing equations with serum creatinine, like the one developed by MDRD study. However, there are doubts about the performance of this equation in normal range GFRs and new formulas have been proposed. Aim: To evaluate the performance of MDRD and Mayo Clinic Quadratic (MCQ) equations in estimating GFR comparing them with 51Cr-EDTA measured GFR in healthy adults. Patients and methods: Cross-sectional study. GFR was measured by 51Cr-EDTA single-injection method and estimated by MDRD e MCQ equations. Serum creatinine was measured with a traceable, compensated Jaffé method. Results: Ninety-six individuals, 61 women (64%), 83 white (86%), aged 42±15 years (19-86 years) were evaluated. 51Cr-EDTA GFR (51CrGFR) was 112±24, MDRDGFR was 94±19 and MCQGFR was 113±15 ml/min/1.73 m2. Bias (measured minus estimated value) between 51CrGFR and MDRDGFR was 18.3 ml/min/1.73 m2, and agreement limits (mean±2 SD) -34 to 70 ml/min/1.73 m2. Bias between 51CrGFR and MCQGFR was -1.4 ml/min/1.73 m2 (-51 a 49 ml/min/1.73 m2). Accuracy, calculated as the proportion of estimated results that deviate less than 15% of the measured value, was 40% for MDRDGFR and 48% for MCQGFR. Conclusion: The available formulas to estimate GFR are not accurate enough to express the measured variable in normal ranges.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectFalência renal crônicapt_BR
dc.subjectTaxa de filtração glomerularpt_BR
dc.subjectDietapt_BR
dc.subjectComportamento alimentarpt_BR
dc.subjectEstudo de validaçãopt_BR
dc.titleDesempenho da taxa de filtração glomerular estimada pelas fórmulas do estudo MDRD e equação quadrática mayo em adultos saudáveispt_BR
dc.typeDissertaçãopt_BR
dc.contributor.advisor-coCamargo, Joiza Linspt_BR
dc.identifier.nrb000690754pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Medicinapt_BR
dc.degree.programPrograma de Pós-Graduação em Ciências Médicas: Endocrinologiapt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2008pt_BR
dc.degree.levelmestradopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples