Disartrofonia em pacientes com doença de Parkinson submetidos à estimulação cerebral profunda (ECP) : frequência de estímulo
dc.contributor.advisor | Rieder, Carlos Roberto de Mello | pt_BR |
dc.contributor.author | Cruz, Aline Nunes da | pt_BR |
dc.date.accessioned | 2017-05-10T02:24:02Z | pt_BR |
dc.date.issued | 2016 | pt_BR |
dc.identifier.uri | http://hdl.handle.net/10183/157667 | pt_BR |
dc.description.abstract | BASE TEÓRICA A Estimulação cerebral profunda (ECP) do núcleo subtalâmico (NST) é utilizada para tratar pacientes com doença de Parkinson (DP) idiopática quando os sintomas não têm boa resposta com a terapia farmacológica. No entanto, a ECP provoca alterações na voz e na fala dos sujeitos implantados. OBJETIVO Esse trabalho teve como objetivo analisar aspectos de voz e fala em pacientes com DP que foram submetidos à implantação da ECP com diferentes frequências de estímulo. MÉTODO Foram avaliados 19 pacientes com DP submetidos ao implante de ECP no NST, em tratamento estabilizado e sob efeito da medicação antiparkinsoniana. As avaliações da voz e da fala foram realizadas de forma randomizada com frequência de estímulo alta (130 Hz) e baixa (60 Hz). CONCLUSÃO Através desse estudo percebemos que os pacientes com DP apresentaram desempenhos diferentes na voz e na fala nas frequências alta e baixa de estímulo da ECP. Aspectos de voz tiveram melhora em 130 Hz e a estimulação de baixa frequência teve um impacto positivo em aspectos da fala, sugerindo que ambas as frequências podem trazer benefícios em alguns aspectos e prejudicar outros na comunicação dos pacientes. | pt_BR |
dc.description.abstract | BACKGROUND: The subthalamic nucleus deep brain stimulation (STN-DBS) is used to treat patients with Parkinson’s disease (DP) when the symptoms do not respond adequately to the pharmacological therapy. OBJECTIVE: This research aimed to investigate the effect of the frequency of stimulation on aspects of voice and speech in patients with PD who were submitted to bilateral STN-DBS. METHODS: The study evaluated 19 patients with PD and STN-DBS who were on stabilized treatment, and on antiparkinson medication effect. The evaluations of voice and speech were performed in a randomized way in the conditions of high frequency (130 Hz) and low frequency (60 Hz) of stimulation. CONCLUSION: Patients with PD showed different outcomes of voice and speech in the high and low frequency of DBS. Voice aspects showed amelioration in 130 Hz, while the low frequency of stimulation presented a positive impact on speech aspects. The findings suggest that both frequency conditions may lead to benefits in some aspects of the patient's communication, but impairments in others. | en |
dc.format.mimetype | application/pdf | pt_BR |
dc.language.iso | por | pt_BR |
dc.rights | Open Access | en |
dc.subject | Parkinson’s disease | en |
dc.subject | Estimulação encefálica profunda | pt_BR |
dc.subject | Deep brain stimulation | en |
dc.subject | Doença de Parkinson | pt_BR |
dc.subject | Voice | en |
dc.subject | Voz | pt_BR |
dc.subject | Fala | pt_BR |
dc.subject | Speech | en |
dc.subject | Dysarthophonia | en |
dc.title | Disartrofonia em pacientes com doença de Parkinson submetidos à estimulação cerebral profunda (ECP) : frequência de estímulo | pt_BR |
dc.type | Dissertação | pt_BR |
dc.identifier.nrb | 001016855 | pt_BR |
dc.degree.grantor | Universidade Federal do Rio Grande do Sul | pt_BR |
dc.degree.department | Faculdade de Medicina | pt_BR |
dc.degree.program | Programa de Pós-Graduação em Medicina: Ciências Médicas | pt_BR |
dc.degree.local | Porto Alegre, BR-RS | pt_BR |
dc.degree.date | 2016 | pt_BR |
dc.degree.level | mestrado | pt_BR |
Este item está licenciado na Creative Commons License
-
Ciências da Saúde (9085)Ciências Médicas (1556)