Mostrar registro simples

dc.contributor.advisorVaz, Marco Aureliopt_BR
dc.contributor.authorLanferdini, Fábio Junerpt_BR
dc.date.accessioned2016-11-10T02:20:09Zpt_BR
dc.date.issued2016pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/149564pt_BR
dc.description.abstractA análise das variáveis associadas à fadiga muscular durante protocolos de ciclismo até a exaustão (incremental e carga constante), ou mesmo simulados (contrarrelógio), e suas implicações em parâmetros cinéticos e cinemáticos, têm sido descritas na literatura em modelos experimentais. Alterações encontradas nas articulações do quadril, joelho e tornozelo, associadas a mudanças no direcionamento das forças aplicadas ao pedal (melhora da técnica de pedalada) durante testes de ciclismo incrementais e/ou constantes, parecem estar relacionados a estratégias musculares intrínsecas para manutenção do trabalho e postergar os efeitos da fadiga. Entretanto, evidências suportam que a aplicação de Laserterapia de Baixa Potência (LBP) reduz os efeitos da fadiga muscular sobre o desempenho, principalmente em modalidades esportivas com um grande componente aeróbico, tal como o ciclismo. Entretanto, ainda não está claro na literatura qual a dosagem ideal de LBP a ser utilizada nessas atividades. Portanto, o objetivo deste estudo foi investigar os efeitos de diferentes dosagens de LBP sobre o desempenho em teste de tempo de exaustão em ciclistas. Além disso, foi analisado os efeitos do LBP sobre o conteúdo de frequências dos sinais de EMG e a cinética de VO2 durante os testes de exaustão. Vinte ciclistas competitivos do sexo masculino participaram de um estudo, randomizado, duplocego e placebo-controlado. Os atletas realizaram teste incremental de ciclismo até a exaustão (dia 1) para determinar o consumo máximo de oxigênio (VO2MÁX) e a potência máxima (POMÁX), seguido de outros quatro testes até a exaustão (dias 2 a 5) na POMÁX do teste incremental. Antes de cada teste de exaustão, diferentes dosagens de LBP (3, 6 e 9 J/diodo, ou 135, 270 e 405 J/coxa, respectivamente) ou placebo. Aumento do desempenho nos testes de exaustão foi observado com a LBP-3J (~22 s; p < 0,01), LBP-6J (~13 s; p = 0,03) e LBP- 9J (~13 s; p = 0,02), comparado com o placebo (149 ± 23 s). Embora LBP-6J e LBP-9J não aumentaram a ativação muscular em comparação com o placebo, a LBP-3J, aumentou a ativação das bandas de alta frequência em comparação com o placebo no final do teste de exaustão, em ambos os membros inferiores (p ≤ 0,03). Os resultados na cinética de VO2, resultaram e redução do constante de tempo (Tau) e déficit de O2 com a aplicação de LBP comparado ao placebo (p < 0,05). Não foram encontradas diferenças (p > 0,05) entre as condições experimentais para amplitude de VO2 e tempo de atraso do VO2. Em conclusão, nosso estudo demonstrou que a fototerapia pode ser um agente ergogênico eficaz para aumentar o desempenho de ciclistas (independente da dose utilizada), e isto se deve ao aumento da ativação das bandas de alta frequência (LBP-3J), bem como da redução do Tau e déficit de O2 (LBP-3 6 e 9J), durante testes máximos de ciclismo até a exaustão.pt_BR
dc.description.abstractThe analysis of muscle fatigue variables during cycling protocols to exhaustion (incremental and constant load) or simulated (time trial), and its implications on kinetic and kinematic parameters, has been described in the literature for experimental models. Changes in hip, knee and ankle joints (such as increased range of motion and reduced ankle contribution to the total joint torque), associated with changes in the direction of the forces applied to the pedal (improved pedaling technique) during cycling tests, seems to be related to strategies for maintaining muscle work in order to postpone fatigue effects. However, evidences supports that application of low-level laser therapy (LLLT) minimizes fatigue effects on muscle performance. However, the ideal LLLT dosage to improve athletes’ performance during sports activities, such as cycling, is still unclear. Therefore, the goal of this study was to investigate the effects of different LLLT dosages on cyclists’ performance during a time-to-exhaustion test. In addition, we looked at the effects of LLLT on the frequency content of the EMG signals and kinetics of VO2 to assess fatigue mechanisms. Twenty male competitive cyclists participated in a crossover, randomized, double-blind and placebo controlled trial. They performed an incremental cycling test to exhaustion (day 1) determine maximal oxygen output (VO2MAX) and maximal power output (POMAX) followed by four time-to-exhaustion tests (days 2 to 5) at their individual POMAX. Before each time to exhaustion test, different LLLT dosages (3, 6 and 9 J/diode; or 135, 270 and 405 J/thigh, respectively) or placebo were applied at the quadriceps muscle bilaterally. Power output and muscle activation from both lower limbs were acquired throughout the tests. Increased performance at the exhaustion tests was observed with the LLLT-3J (~22 s; p < 0.01), LLLT-6J (~13 s; p = 0.03) and LLLT-9J (~13 s; p = 0.02) compared to placebo (149 ± 23 s). Although LLLT-6J and LLLT-9J did not show significant differences in muscle activation compared to placebo, LLLT-3J led to an increased high frequency content compared to placebo in both limbs at the end of the exhaustion test (p ≤ 0.03). The results in kinetics VO2, resulting in reduction of time constant (Tau) and deficit O2 with LLLT applications compared to the placebo condition (p < 0.05). No differences (p > 0.05) were found between the experimental conditions for VO2 amplitude and VO2 delay time. In conclusion, this study has shown that the phototherapy can be an effective ergogenic agent to increase cycling performance (regardless of the dose used), and this is due to increased activation of the high frequency bands (LLLT-3J) as well as the reduction of Tau and deficit of O2 (LLLT-3, 6 and 9J), during maximum cycling exhaustion test.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectCiclismopt_BR
dc.subjectLaser therapy dosageen
dc.subjectFototerapiapt_BR
dc.subjectPhototherapyen
dc.subjectCyclingen
dc.subjectCinesiologia aplicadapt_BR
dc.subjectFatigueen
dc.subjectExhaustionen
dc.subjectForces and kinematics pedalingen
dc.subjectVO2 kineticsen
dc.subjectPerformanceen
dc.titleEfeito da dose de laserterapia de baixa potência sobre o desempenho em teste de ciclismopt_BR
dc.typeTesept_BR
dc.identifier.nrb001006487pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentEscola de Educação Físicapt_BR
dc.degree.programPrograma de Pós-Graduação em Ciências do Movimento Humanopt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2016pt_BR
dc.degree.leveldoutoradopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples