Mostrar registro simples

dc.contributor.advisorRibeiro, Jose Luis Duartept_BR
dc.contributor.authorBotelho, Heitor Cabralpt_BR
dc.date.accessioned2016-10-21T02:18:20Zpt_BR
dc.date.issued2016pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/149187pt_BR
dc.description.abstractNas indústrias química e petroquímica o uso de sistemas redundantes é comum. Exceto pelos programas de lubrificação, a estratégia de manutenção adotada para estes sistemas é, principalmente, a manutenção corretiva. Os objetivos desta dissertação são, a partir do registro do histórico de falhas dos equipamentos de uma unidade fabril petroquímica e conceitos de confiabilidade, estimar o tempo limite que estes sistemas podem operar sem intervenções de manutenção, mantendo a disponibilidade do sistema em níveis adequados. Esse tempo limite foi usado para desenvolver um indicador a ser utilizado no processo de priorização das atividades de manutenção. Para atingir os objetivos foram desenvolvidas as seguintes etapas: a) revisão dos dados de confiabilidade; b) elaboração de modelagem de sistemas de bombeamento. Inicialmente foi realizada uma revisão dos dados de confiabilidade coletados pela empresa em estudo, a partir da qual se obteve análise dos problemas encontrados com os dados, sumário de procedimentos a serem adotados para cada tipo de problema e sugestões para evitar sua reincidência. Por meio dos resultados iniciais, foi elaborada a modelagem de sistemas de bombeamento, utilizando o método de Monte Carlo. Obtevese, como resultado, curvas de disponibilidade do sistema versus tempos para reparo. O método proposto é simples de ser utilizado em campo e, definida a disponibilidade desejada para o sistema redundante, permite o cálculo do máximo tempo para reparo do equipamento em falha.pt_BR
dc.description.abstractIn chemical and petrochemical industries redundant systems are usual. Except by lubrication programs, the maintenance strategy adopted for these systems is mainly corrective maintenance. Considering the historical failure records of the equipment of a factory and the use of reliability concepts, the goal of this work is to estimate the maximum time that these systems can operate without maintenance interference, while keeping the system availability on adequate levels. This maximum time was used to develop an indicator to be used in the process of prioritization of maintenance activities. To achieve these goals, the following steps have been developed: a) reliability data review; b) elaboration of a pumping system model. Initially, a review of the reliability data collect at the studied company was performed, from which an analysis of the problems encountered at these data, a summary of procedures to be adopted for each type of problem, and suggestions to avoid its recurrence were established. As a consequence of first results, a model for each pumping system using the Monte Carlo method was developed and availability curves of the system versus time to repair were obtained. The proposed method is simple to use in the field and, considering the desired availability for the redundant system, it allows the calculation of the maximum time to repair equipment failures.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectReliabilityen
dc.subjectAnálise de confiabilidadept_BR
dc.subjectTime to repairen
dc.subjectAnálise de falhaspt_BR
dc.subjectManutenção industrialpt_BR
dc.subjectCold standbyen
dc.subjectMonte Carloen
dc.subjectRedundancyen
dc.subjectFailure dataen
dc.subjectAvailabilityen
dc.subjectMaintenanceen
dc.titleAnálise dos tempos de reparo em sistemas redundantes do tipo Cold Standby com alternânciapt_BR
dc.typeDissertaçãopt_BR
dc.identifier.nrb001004713pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentEscola de Engenhariapt_BR
dc.degree.programPrograma de Pós-Graduação em Engenharia de Produçãopt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2016pt_BR
dc.degree.levelmestrado profissionalpt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples