dc.description.abstractO presente estudo visa à obtenção de um modelo utilizando o acoplamento dos códigos WRF e CALPUFF com o objetivo de obter as características do campo meteorológico e da dispersão dos poluentes NO2 e SO2 de uma Usina Termelétrica localizada em Linhares. Foi utilizada uma grade de 100×100 células, com resolução de 1 km durante 90 h. Para vias de comparação, outra simulação foi feita sem a entrada do modelo WRF no CALMET, utilizando uma grade 15×15 sem modificar nenhum outro parâmetro. Os resultados obtidos foram comparados com dados do aeroporto de Vitória e com a legislação ambiental vigente. Para a camada limite planetária, o resultado obtido da simulação WRF/CALMET se encontra dentro da faixa encontrada na literatura. Os demais resultados, média de velocidade e direção do vento, para as duas simulações diferem entre si e dos dados do aeroporto, fato que já era esperado devido à distância e orografia entre a Usina e os dados da estação utilizados como entrada nos modelos. A concentração máxima obtida para os poluentes estudados se encontram dentro dos padrões de qualidade do ar. Devido à falta de dados observacionais, não foi possível uma genuína validação dos resultados, mas, sabendo a localização dos picos, foi possível sugerir locais de amostragem para futura comprovação dos resultados.pt_BR
dc.description.abstractThis study aims to create a model using the coupling of the WRF and CALPUFF codes in order to obtain characteristics of the meteorological field and the dispersion of pollutants NO2 and SO2 of a power plant located at the city of Linhares. The field consists of a grid of 100×100 cells resolution of 1 km for 90 h. Another simulation was made without using WRF as an input into CALMET, in the purpose of comparison, using a 15×15 grid and no change of other parameters. The results were compared to data from the airport of Vitória and against environmental legislation. For the planetary boundary layer the results of WRF/CALMET simulation are within the range found in the literature. The results of average wind speed and direction obtained by both simulations are different from each other and from the data of the airport,such as expected due to the distance and orography of the power plant and station data used as input into the models. The maximum concentrations of the pollutants are within air quality standards. Due to lack of observational data, genuine validation of the results is not feasible, but knowing the location of the concentration peak, it was possible to propose suitable sampling sites for future verification.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectDispersionen
dc.subjectDispersão de poluentespt_BR
dc.subjectUsinas termelétricaspt_BR
dc.subjectCALPUFFen
dc.subjectWRFen
dc.subjectModelos matemáticospt_BR
dc.subjectAir qualityen
dc.subjectModelen
dc.titleEstudo da dispersão de poluentes em uma usina termelétrica localizada em linhares utilizando o modelo Calpuffpt_BR
dc.typeDissertaçãopt_BR
dc.contributor.advisor-coBodmann, Bardo Ernst Josefpt_BR
dc.identifier.nrb001001822pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentEscola de Engenhariapt_BR
dc.degree.programPrograma de Pós-Graduação em Engenharia Mecânicapt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2016pt_BR
dc.degree.levelmestradopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples