Fragmentação de DNA em espermatozoides humanos com diferentes viscosidades no plasma seminal
dc.contributor.advisor | Corleta, Helena von Eye | pt_BR |
dc.contributor.author | Kussler, Ana Paula de Souza | pt_BR |
dc.date.accessioned | 2015-04-23T01:58:51Z | pt_BR |
dc.date.issued | 2012 | pt_BR |
dc.identifier.uri | http://hdl.handle.net/10183/115495 | pt_BR |
dc.description.abstract | Introdução: Doze a 29 % dos ejaculados tem viscosidade seminal aumentada. Uma das técnicas recomendadas para diminuir a viscosidade do sêmen consiste num processo físico em que se passa o sêmen, 4 vezes, por uma seringa de 10 mL com agulha 18G. Ao fim desse processo, ter-se-ia modificado o comportamento molecular das fibrilas protéicas do esperma, tornando-o mais liquefeito, sem dano aparente a morfologia ou motilidade dos espermatozoides. Atualmente, discute-se sobre a total inocuidade desta técnica, uma vez que ela poderia provocar aumento da fragmentação do DNA dos espermatozoides. A hiperviscosidade seminal, além de reduzir a concentração e a motilidade dos espermatozoides, pode afetar a capacitação e a reação acrossômica, podendo ter implicações na integridade do DNA e no desenvolvimento embrionário normal. Objetivo: Comparar a fragmentação do DNA de espermatozoides humanos em amostras com viscosidade diminuída, fisiológica e aumentada, e avaliar se o processo de expulsão do sêmen através da agulha e seringa altera significativamente as taxas de fragmentação do DNA dos espermatozoides. Método: Após a coleta e avaliação dos parâmetros seminais das amostras de sêmen, aquelas que estiverem com viscosidade aumentada passarão pelo processo de expulsão através da seringa de 10 mL com agulha 18G por 4 vezes, para diminuir a viscosidade seminal. Posteriormente, serão feitas análises da fragmentação do DNA dos espermatozoides através da técnica de TUNEL em todas as amostras. Resultados: A fragmentação do DNA entre amostras com viscosidade fisiológica, diminuída e aumentada não apresentou diferença estatisticamente significativa (P=0,857). A fragmentação do DNA aumentou significativamente (P=0,035) nas amostras com viscosidade aumentada após passar na seringa e agulha quando comparadas com as mesmas amostras antes de passar pela mesma. Conclusão: O processo de expulsão do sêmen através de seringa e agulha visando redução da viscosidade seminal aumenta a fragmentação do DNA no espermatozoide, devendo este processo ser substituído por um processo inócuo. | pt_BR |
dc.description.abstract | Background: Twelve to 29 % of the ejaculated have the semen viscosity increased. One of the techniques recommended to decrease the viscosity of semen is a physical process in which the semen passes four times through a 10mL syringe with a 18G needle. At the end of this process would have modified the molecular behavior of the protein fibrils of the sperm making it more liquefied, without apparent damage to the morphology or motility of spermatozoa. Currently, the debate is about the complete safety of this technique since it could result in increased DNA fragmentation of spermatozoa. The seminal viscosity moreover reduces the concentration and motility of sperm, can affect the capacitation and acrosome reaction which may have implications for DNA integrity and normal embryonic development. Objective: To compare the DNA fragmentation in human semen samples with reduced, physiological and increased viscosity and evaluate if the process of expulsion of semen through the needle and syringe significantly alter rates of sperm DNA fragmentation. Methods: After collecting and evaluating semen parameters of semen samples, those that are with increased viscosity will pass through the process of expulsion through the 10 mL syringe with a 18G needle four times to reduce the viscosity of semen. After that, analysis of spermatozoa DNA fragmentation through the TUNEL technique will be made in all samples. Results: The fragmentation of DNA between samples with physiological, reduced and increased viscosity is not statistically significant (P=0.857). The DNA fragmentation increased significantly (P=0.035) in samples with increased viscosity after passing the syringe and needle when compared with the same samples before going through the same. Conclusion: The process of expulsion of semen through a syringe and needle in order to reduce the semen viscosity increases the DNA fragmentation in sperm, and this shall be replaced by a harmless process. | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | por | pt_BR |
dc.rights | Open Access | en |
dc.subject | Semen | en |
dc.subject | Sêmen | pt_BR |
dc.subject | Espermatozóides | pt_BR |
dc.subject | Spermatozoa | en |
dc.subject | DNA fragmentation | en |
dc.subject | Fragmentação do DNA | pt_BR |
dc.subject | Viscosidade | pt_BR |
dc.subject | Viscosity | en |
dc.title | Fragmentação de DNA em espermatozoides humanos com diferentes viscosidades no plasma seminal | pt_BR |
dc.type | Dissertação | pt_BR |
dc.identifier.nrb | 000822096 | pt_BR |
dc.degree.grantor | Universidade Federal do Rio Grande do Sul | pt_BR |
dc.degree.department | Faculdade de Medicina | pt_BR |
dc.degree.program | Programa de Pós-Graduação em Medicina: Ciências Médicas | pt_BR |
dc.degree.local | Porto Alegre, BR-RS | pt_BR |
dc.degree.date | 2012 | pt_BR |
dc.degree.level | mestrado | pt_BR |
Files in this item
This item is licensed under a Creative Commons License
-
Health Sciences (9127)Medical Sciences (1557)