Mostrar registro simples

dc.contributor.authorBreitsameter, Guilhermept_BR
dc.contributor.authorFigueiredo, Ana Elizabeth Prado de Limapt_BR
dc.contributor.authorKochhann, Daiana Sautept_BR
dc.date.accessioned2015-04-17T01:57:58Zpt_BR
dc.date.issued2012pt_BR
dc.identifier.issn0101-2800pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/115382pt_BR
dc.description.abstractIntrodução: A qualidade da diálise oferecida aos pacientes em diálise pode ser mensurada pelo Kt/V, o qual pode ser calculado de diversas maneiras. Objetivo: Comparar os resultados de Kt/V obtidos por meio das fórmulas de Lowrie (L) e de Daugirdas (D) com os resultados mensurados pelo monitor de clearence on-line – Online Clearence Monitor (OCM). Método: Estudo observacional transversal com 59 pacientes em hemodiálise (HD). Os dados foram coletados na mesma sessão de diálise: (ureia pré-diálise e pós-diálise) e o resultado de Kt/V foi obtido pelo OCM da máquina Fresenius 4008S (Fresenius Medical Care AG, Bad Homburg, Alemanha). Resultado: Foram analisadas 95 sessões, em que prevaleceu o sexo masculino, 56% (33), com idade média de 57 + 14 anos. A hipertensão arterial com 42% (25), diabetes com 12% (7) e glomerulonefrite com 8% (5) foram as causas mais frequentes da doença renal crônica (DRC). O Kt/V médio obtido pela fórmula de L, de D e pelo OCM foi de 1,31; 1,41 e 1,32, respectivamente. A comparação entre as fórmulas de L e D mostra que há diferença estatística p = 0,008 com a correlação de Pearson de 0,950. Entre D e OCM a diferença também é significativa: p = 0,011 e r = 0,346, provavelmente devido a perda convectiva, avaliada pela equação de D e não observadas por OCM e L. A comparação entre L e OCM não foi significativa p = 0,999 e r = 0,577. Conclusão: Os dados sugerem que o OCM pode ser utilizado como um norteador para ajuste da dose de diálise em tempo real.pt_BR
dc.description.abstractIntroduction: The quality of delivered dialysis can be measured by the Kt/V ratio, which can be calculated in various ways. Objective: To compare the Kt/V ratio obtained with the formulas of Lowrie (L) and Daugirdas (D) with the results measured by an Online Clearance Monitor (OCM). Method: Observational, cross-sectional study of 59 patients on hemodialysis (HD). Data were collected in the same dialysis session (predialysis and postdialysis urea) and Kt/V was calculated by the OCM of the Fresenius 4008S machine (Fresenius Medical Care AG, Bad Homburg, Germany). Results: A total of 95 sessions were assessed, with a predominance of males 56% (33), and a sample mean age of 57 + 14 years. Hypertension (42%; n = 25), diabetes (12%; n = 7) and glomerulonephritides (8%; n = 5) were the most frequent causes of chronic kidney disease (CKD). Mean Kt/V values obtained with the L and D formulas and the OCM were 1.31, 1.41 and 1.32, respectively. Comparison between the L and D formulas showed a statistically significant difference (p = 0.008), with a Pearson`s correlation of 0.950. The difference between the D formula and the OCM was also significant (p = 0.011 and r = 0.346), probably due to convective loss, estimated by the D formula but not by the OCM and L formula. The difference between the L formula and the OCM was not significant (p = 0.999 and r = 0.577). Conclusion: These data suggest that the OCM can be used as a guide to the real-time adjustment of the dialysis dose.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.relation.ispartofJornal brasileiro de nefrologia = Brazilian journal of nephrology. Vol. 34, n. 1 (jan./mar. 2012), p. 22-26pt_BR
dc.rightsOpen Accessen
dc.subjectDialysisen
dc.subjectProteinúriapt_BR
dc.subjectRenal insufficiency chronicen
dc.subjectCreatininapt_BR
dc.subjectUrinapt_BR
dc.subjectQuality controlen
dc.titleCálculo de Kt/V em hemodiálise : comparação entre fórmulaspt_BR
dc.title.alternativeCalculation of Kt/V in haemodialysis : a comparison between the formulasen
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb000943709pt_BR
dc.type.originNacionalpt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples