dc.description.abstractEste trabalho é um estudo da aplicação de um sistema que utiliza a cogeração para hotéis localizados na cidade de Porto Alegre, RS, Brasil. Foi analisada a implantação desse tipo de sistema, também chamado de CHP (Combined Heat and Power), de um ponto de vista econômico e energético. A questão econômica foi determinada pela viabilidade através de métodos de análise quantitativa, neste caso, dando enfoque ao tempo de retorno do investimento. Para a análise energética foi realizado o estudo dos consumos e demandas anuais da operação do prédio através da ferramenta de simulação térmo-energética de edificações. O software escolhido foi o EnergyPlus. Essas análises, energéticas e econômicas, foram realizadas através de uma comparação entre o hotel sem o sistema de CHP e o hotel com o sistema de CHP. O hotel hipotético simulado foi definido através de um levantamento de informações a respeito do desempenho energético de hotéis que funcionam em Porto Alegre. Além dos estudos energéticos e econômicos, foram realizadas variações em parâmetros do hotel para tentar abranger uma série de possíveis cenários e verificar suas viabilidades econômicas. Foi visto que a cogeração pode trazer redução de custo operacional mesmo não tendo um menor consumo energético anual. Em alguns cenários o tempo de retorno do investimento apresentou valor abaixo dos seis anos, sendo considerado como uma boa opção de investimento.pt_BR
dc.description.abstractThis work is a study of the application of a CHP (Combined Heat and Power) system in hotels built in the city of Porto Alegre, RS, Brazil. This system was analyzed from an economic and energetic point of view. The economic matter on its viability perspective was determined through quantitative methods, in this case, with the focus on the time frame for the investment's return. For the energetic analysis, a annual energy consumption and demand study was performed utilizing a whole-building energy model with computer simulation. The chosen software was EnergyPlus. The analyses, energetic and economic, were performed through a comparison between the hotel without the CHP system and with the CHP system. The hypothetic simulated hotel was determined by a data survey on the energetic performance of hotels build in Porto Alegre. In addition to the energetic and economic studies, some parametric variations to the hotel were made to include a series of possible scenarios and check their economic viability. It was observed that the CHP can provide some operational cost reductions even without presenting a lower annual energetic consumption. In some scenarios, the time to return the investment showed figures lower than six years, being considered a good investment option.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectCogenerationen
dc.subjectAnálise quantitativapt_BR
dc.subjectConsumo de energiapt_BR
dc.subjectCHPen
dc.subjectWhole-building energy model simulationen
dc.subjectCogeração de energiapt_BR
dc.subjectEnergyplusen
dc.subjectSimulação computacionalpt_BR
dc.subjectHotéispt_BR
dc.titleEstudo de cogeração em hotéispt_BR
dc.typeDissertaçãopt_BR
dc.identifier.nrb000946394pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentEscola de Engenhariapt_BR
dc.degree.programPrograma de Pós-Graduação em Engenharia Mecânicapt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2014pt_BR
dc.degree.levelmestradopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples