Mostrar el registro sencillo del ítem
Análise quantitativa do artefato induzido por núcleos fundidos em duas diferentes ligas metálicas em imagens de microtomografia
dc.contributor.advisor | Fontanella, Vania Regina Camargo | pt_BR |
dc.contributor.author | Bourscheid, Daiana Spessatto | pt_BR |
dc.date.accessioned | 2022-04-07T04:47:48Z | pt_BR |
dc.date.issued | 2019 | pt_BR |
dc.identifier.uri | http://hdl.handle.net/10183/236675 | pt_BR |
dc.description.abstract | O presente estudo in vitro teve por objetivo quantificar a intensidade do artefato produzido por microtomografia computadorizada na presença de retentores intrarradiculares fundidos em cobre-alumínio-zinco e níquel-cromo. Para tanto, 25 incisivos bovinos de dimensões semelhantes e tratados endodonticamente foram utilizados. Para cada um deles houve a fundição dois núcleos com diferentes ligas metálicas: cobre-alumínio-zinco (CAZ) e níquel-cromo (NC). Os dentes foram submetidos à microtomografia no equipamento InspeXio SMX-90CT® - Shimadzu Benchtop Microfocus X-Ray CT System e as imagens preparadas no software RadiAnt DICOM Viewer®. Para cada volume adquirido foram selecionadas três imagens de cortes axiais: a mais apical que registrasse toda a circunferência do retentor (A); a mais cervical que registrasse toda a circunferência radicular (C); e a intermediária aos dois cortes anteriormente descritos, representativa do terço médio do retentor (M). As três imagens das diferentes ligas foram avaliadas quanto à variação do desvio-padrão da intensidade de pixel na dentina. Um segundo pesquisador, previamente, calibrado (ICC=0,997; p=0,000) realizou a análise das imagens sob condições padronizadas. O artefato gerado pelo metal foi expresso pelo desvio-padrão da intensidade de pixels da dentina; as ligas foram comparadas pelos Testes de Wilcoxon (NC: 13,75; CAZ: 12,35 - p≤0,01); e os terços pelo Teste de Friedman (maior no terço médio - p≤0,01). Conclui-se que a liga NC produziu, significativamente, mais artefato ao ser comparada à liga CAZ em imagens de μCT. O terço médio do retentor apresentou a maior intensidade de artefato para as duas ligas. | pt_BR |
dc.description.abstract | This in vitro study aimed to quantify the intensity of the artifact produced by microtomography in presence of copper-aluminum-zinc and nickel-chromium post and cores. For this purpose, 25 bovine incisors with similar dimensions were endodontically treated and for each of them, two post and cores with different alloys were cast: copper-aluminum-zinc (CAZ) and nickel-chromium (NC). The teeth were submitted to microtomography in InspeXio SMX-90CT® - Shimadzu Benchtop Microfocus X-Ray CT System and the images were prepared in RadiAnt DICOM Viewer® software. For each volume acquired, three images of axial sections were selected: the most apical that recorded the entire circumference of the retainer (A); the most cervical that registers the whole radicular circumference (C); and the intermediate one to the two cuts described above, representative of the middle third of the retainer (M). The three images with different metal posts were evaluated for the standard deviation of the pixel intensity in dentin. A second examiner, previously calibrated (ICC=0,997; p=0,000) analyzed the images under standardized conditions. The artifact generated by the metal was expressed by the standard deviation of the pixel intensity of the dentin; the two alloys were compared by Wilcoxon Test (NC: 13.75; CAZ: 12.35 - p≤0.01); and the differences among thirds were evaluated by Friedman Test (higher in the middle third - p≤0.01). It was concluded that NC alloy produced, significantly, more artifact when compared to CAZ alloy at μCT images. The middle third of the retainer presented more artefact for the two alloys. | en |
dc.format.mimetype | application/pdf | pt_BR |
dc.language.iso | por | pt_BR |
dc.rights | Open Access | en |
dc.subject | Post and core technique | en |
dc.subject | Técnica para retentor intrarradicular | pt_BR |
dc.subject | Microtomografia por raio-x | pt_BR |
dc.subject | X-Ray microtomography | en |
dc.subject | Artefatos | pt_BR |
dc.subject | Artifacts | en |
dc.title | Análise quantitativa do artefato induzido por núcleos fundidos em duas diferentes ligas metálicas em imagens de microtomografia | pt_BR |
dc.type | Trabalho de conclusão de graduação | pt_BR |
dc.identifier.nrb | 001112006 | pt_BR |
dc.degree.grantor | Universidade Federal do Rio Grande do Sul | pt_BR |
dc.degree.department | Faculdade de Odontologia | pt_BR |
dc.degree.local | Porto Alegre, BR-RS | pt_BR |
dc.degree.date | 2019 | pt_BR |
dc.degree.graduation | Odontologia | pt_BR |
dc.degree.level | graduação | pt_BR |