Mostrar registro simples

dc.contributor.authorTerraciano, Paula Barrospt_BR
dc.contributor.authorBustamante, Ivanpt_BR
dc.contributor.authorMiquelito, Ludmila do Valept_BR
dc.contributor.authorArlas, Tamarinipt_BR
dc.contributor.authorCastro, Fabiana Santospt_BR
dc.contributor.authorMattos, Rodrigo Costapt_BR
dc.contributor.authorPassos, Eduardo Pandolfipt_BR
dc.contributor.authorOberst, Eneder Rosanapt_BR
dc.contributor.authorLima, Elizabeth Obino Cirnept_BR
dc.date.accessioned2010-05-13T04:16:37Zpt_BR
dc.date.issued2008pt_BR
dc.identifier.issn0103-8478pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/21995pt_BR
dc.description.abstractDurante o processo de criopreservação de sêmen, os espermatozóides sofrem alguns danos que resultam na diminuição da fertilidade deste. O presente estudo foi realizado com o objetivo de avaliar os efeitos da utilização combinada de duas curvas de congelamento com dois diluentes comerciais (FR-5® e Botu-Crio®) sobre a criopreservação de sêmen eqüino. Foram analisados 20 ejaculados de dois garanhões. As amostras foram avaliadas por microscopia de contraste de fase e microscopia de epifluorescência, observando-se a motilidade progressiva e total do sêmen pós-descongelamento e a integridade e a funcionalidade da membrana dos espermatozóides. A combinação entre curva automatizada e Botu-Crio® apresentou as maiores médias nas análises de motilidade total e progressiva, após o descongelamento. O diluente Botu-Crio®, isoladamente, preservou também as membranas destes, quando foram realizadas as análises de integridade utilizando teste com diacetato de carboxifluoresceína e iodeto de propídio e funcionalidade de membrana pelo teste hiposmótico.pt_BR
dc.description.abstractDuring semen cryopreservation, sperm cells were submitted to several deleterious events leading to membrane damage which result in fertility decrease. This study was designed to compare the effects of two freezing techniques (conventional and automated), and the use of two commercial extenders as cryoprotectants (FR-5® and Botu-Crio®) on total and progressive motility, integrity and functionality of spermatic membranes during the cryopreservation of equine semen. Twenty ejaculates from two stallions were analyzed. The total and progressive motility of fresh and post-thawing semen samples were evaluated by patterns assays. Function of plasmatic membrane was measured by the hipoosmotic swelling test. Integrity of plasmatic membrane was evaluated using carboxifluorescein diacatate and iodidium propide fluorescent probes. There were significant differences between the two freezing techniques and/or between cryoprotectants for all assessed parameters. The combination of Botu-Crio® and automated curves showed better results on total and progressive post-thawing motility. The extender Botu- Crio®, alone, showed to better preserve the membrane integrity and function.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.relation.ispartofCiência rural. Santa Maria. Vol. 38, n.7 (out. 2008), p. 1972-1977pt_BR
dc.rightsOpen Accessen
dc.subjectSemenen
dc.subjectCriopreservaçãopt_BR
dc.subjectEquineen
dc.subjectReproducao animal : Equinos : Eventopt_BR
dc.subjectCryopreservationen
dc.subjectSpermatozoon cellen
dc.subjectCryoprotectantsen
dc.titleCriopreservação de espermatozóides eqüinos comparando duas curvas de congelamento combinadas com diferentes diluentes comerciais: uma análise laboratorialpt_BR
dc.title.alternativeCryopreservation of equine spermatozoa comparing different freezing rates combined with commercial extenders: laboratorial analysis en
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb000663634pt_BR
dc.type.originNacionalpt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples