dc.contributor.authorValle, Stella de Fariapt_BR
dc.contributor.authorFarias, Clarice Soares dept_BR
dc.contributor.authorDuda, Naila Cristina Blattpt_BR
dc.contributor.authorMachado, Gustavopt_BR
dc.contributor.authorCosta, Fernanda Vieira Amorim dapt_BR
dc.date.accessioned2019-06-20T02:35:37Zpt_BR
dc.date.issued2019pt_BR
dc.identifier.issn0102-0935pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/195994pt_BR
dc.description.abstractO objetivo do presente estudo foi correlacionar os valores de reticulócitos pontilhados e agregados obtidos por metodologia manual com a metodologia automática de contagem de reticulócitos totais em amostras de sangue de gatos anêmicos, analisados em um contador hematológico com citometria de fluxo. Para isso, 40 amostras de sangue de pacientes felinos anêmicos, independentemente de idade e sexo, foram utilizadas para a determinação das contagens absolutas de reticulócitos totais pela metodologia automatizada por citometria de fluxo fluorescente e pela técnica manual com corante supravital, em duplicata. Na contagem manual, houve a discriminação entre reticulócitos pontilhados e agregados. Para a correlação entre os métodos, foi realizada a análise de regressão de Passing-Bablok. A média do hematócrito dos gatos foi de 15,25%, tendo a maioria dos gatos (32,5%) apresentado anemia moderada (hematócrito = 17,81%). Como resultados, a análise de regressão demonstrou que a correlação entre a contagem absoluta total automática foi superior à contagem manual de reticulócitos agregados (rho= 0,71; P<0,001) do que a contagem absoluta de reticulócitos pontilhados (rho= 0,68; P<0,001). Os resultados apresentados sugerem que a contagem de reticulócitos total absoluta realizada pelo analisador hematológico ProCyte Dx em gatos anêmicos se refere à contagem absoluta de reticulócitos. Dessa maneira, recomenda-se que os valores possam ser utilizados para a avaliação imediata da condição hematológica de gatos anêmicos.pt
dc.description.abstractThe aim of this study was to correlate the punctate and aggregated reticulocytes values obtained by manual methodology and the automatic reticulocyte count in 40 blood samples from anemic cats. Total reticulocyte absolute counts were determined by automated fluorescence flow cytometry and manual methods in 40 blood samples obtained from anemic cats. The manual count was obtained by supravital stain in duplicate to each sample and the reticulocyte morphology were discriminated between punctate and aggregates reticulocytes. Passing-Bablok regression analysis was utilized to compare the methods. Most samples were from anemic cat (15,25%) and the hematocrit mean was 17,81%. Regression analysis showed that the correlation between the absolute total automatic counts is higher with aggregated reticulocytes (rho= 0,71; P< 0,001) than with absolute punctate reticulocytes counts (rho= 0, 68, P< 0.001). Results suggest that the ProCyte Dx reticulocytes count in anemic cats is correlated with aggregate reticulocyte count. Thus, the greater amount of RNA and organelles in aggregate reticulocytes generates a cellular complexity and, therefore, greater impregnation of the dye in an automatic count. Thus, the values obtained by the hematologic instrument can be used for the immediate evaluation of the hematological condition in anemic cats.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.relation.ispartofArquivo brasileiro de medicina veterinária e zootecnia. Belo Horizonte. Vol. 71, n. 2 (2019), p. 577-583pt_BR
dc.rightsOpen Accessen
dc.subjectAnemiaen
dc.subjectContagem de reticulócitospt_BR
dc.subjectFelineen
dc.subjectCitometria de fluxopt_BR
dc.subjectFelinospt_BR
dc.subjectAbsolute reticulocyte counten
dc.subjectAnemiapt_BR
dc.subjectFlow citometryen
dc.titleCorrelação entre as contagens de reticulócitos manual e automática em amostras de felinos anêmicospt_BR
dc.title.alternativeCorrelation between manual and automatized values of reticulocyte count in anemic feline samples en
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb001095706pt_BR
dc.type.originNacionalpt_BR