Mostrar registro simples

dc.contributor.authorAnjos, Tathiana Mourão dospt_BR
dc.contributor.authorVeado, Júlio César Cambraiapt_BR
dc.contributor.authorAraújo, Roberto Baracat dept_BR
dc.contributor.authorLeme, Fabiola de Oliveira Paespt_BR
dc.contributor.authorDiniz, Soraia de Araujopt_BR
dc.contributor.authorCastro, Maria Cristina Nobre ept_BR
dc.contributor.authorCosta, Fernanda Vieira Amorim dapt_BR
dc.contributor.authorTavares , C. A. P.pt_BR
dc.contributor.authorDavid, L. M.pt_BR
dc.contributor.authorQuites, K. X.pt_BR
dc.contributor.authorMaia, M. Q.pt_BR
dc.date.accessioned2018-05-19T03:18:15Zpt_BR
dc.date.issued2016pt_BR
dc.identifier.issn0102-0935pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/178605pt_BR
dc.description.abstractApós validação de dois diferentes métodos de mensuração de pressão arterial sistólica (PAS) não invasivos ou indiretos (oscilométrico e Doppler vascular) com o invasivo ou direto (cateterização arterial  padrão ouro) em 12 gatos hígidos anestesiados de mesma faixa etária, os métodos não invasivos foram avaliados e comparados em 24 gatos hígidos e conscientes, divididos em quatro grupos de idade. Em cada animal, procedeu-se à mensuração da pressão pelos métodos Doppler e oscilométrico. O método oscilométrico foi o primeiro a ser realizado, e, logo em seguida, o método Doppler. Os valores considerados foram obtidos das médias de sete medidas consecutivas para cada método, com intervalo de 30 segundos entre elas. A primeira medida e as medidas discrepantes (variação ˃ 20% PAS), obtidas com sinais óbvios de estresse e/ou com movimentação do animal, foram descartadas. Os métodos de mensuração oscilométrico e Doppler, embora tenham apresentado médias estatisticamente diferentes em todos os grupos, quando comparados em cada grupo, apresentaram uma correlação significativa, alta e positiva. Ou seja, sempre que for obtido um valor elevado por um método, o mesmo fato ocorrerá com o outro método e vice-versa. Clinicamente, a diferença observada não é relevante, uma vez que a diferença média dos valores obtida pelos dois métodos, em cada grupo, foi menor que 1,1%.pt_BR
dc.description.abstractAfter two different validation systolic blood pressure measurement methods (PAS), not invasive or indirect (oscillometric and doppler vascular) with invasive or direct (arterial catheterization - Gold Standard) in 12 anesthetized healthy cats of the same age group, not invasive methods were evaluated and compared in 24 healthy conscious cats, divided into four age groups. In each animal, we proceeded to measure the pressure by Doppler and oscillometric methods. The oscillometric method was the first to be performed, and, shortly thereafter, the doppler method. The values considered were obtained from averages from seven consecutive measurements for each method with an interval of thirty seconds between them. The first measurement and disparate measurements (range ˃ 20% PAS) obtained with obvious signs of stress and / or animal movement were discarded. Methods of oscillometric and doppler measurement, although statistically different averages were shown in all groups when compared, each group showed a significant high positive correlation, meaning that when a high value is obtained by a method, the same occurs with the other method, and vice versa. Clinically, the observed difference is not relevant since the mean difference values obtained by the two methods, in each group was lower than 1.1%.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.relation.ispartofArquivo brasileiro de medicina veterinária e zootecnia. Vol. 68, n. 3 (maio 2016), p. 611-619pt_BR
dc.rightsOpen Accessen
dc.subjectPressão arterialpt_BR
dc.subjectFelineen
dc.subjectDoppleren
dc.subjectMétodo oscilométricopt_BR
dc.subjectOscillometricen
dc.subjectMétodo Dopplerpt_BR
dc.subjectFelinospt_BR
dc.subjectBlood pressureen
dc.titleAvaliação e comparação entre métodos de mensuração de pressão arterial sistólica em gatos hígidos conscientespt_BR
dc.title.alternativeEvaluation and comparison between methods of measurement of systolic blood pressure in healthy conscious cats en
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb001065978pt_BR
dc.type.originNacionalpt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples