Antiparallel interface coupling evidenced by negative rotatable anisotropy in IrMn/NiFe bilayers
Visualizar/abrir
Data
2015Autor
Tipo
Assunto
Abstract
Negative rotatable anisotropy is estimated via ferromagnetic resonance measurements in as-made, annealed, and ion-irradiated IrMn3/Ni81Fe19 bilayers. Opposite to previous observations, inverse correlation between rotatable anisotropy and coercivity is observed. The exchange-bias field, determined from hysteresis loop measurements, is higher than that obtained from ferromagnetic resonance for all samples. The results are discussed in terms of majority antiparallel coupling and magnetic-field-ind ...
Negative rotatable anisotropy is estimated via ferromagnetic resonance measurements in as-made, annealed, and ion-irradiated IrMn3/Ni81Fe19 bilayers. Opposite to previous observations, inverse correlation between rotatable anisotropy and coercivity is observed. The exchange-bias field, determined from hysteresis loop measurements, is higher than that obtained from ferromagnetic resonance for all samples. The results are discussed in terms of majority antiparallel coupling and magnetic-field-induced transitions from antiparallel to parallel states of uncompensated spins at ferromagnet/ antiferromagnet interface. We affirm that an observation of negative rotatable anisotropy evidences antiparallel coupling even in systems presenting conventional exchange bias ...
Contido em
Journal of applied physics. New York. Vol. 117, no. 21 (June 2015), 215301, 6 p.
Origem
Estrangeiro
Coleções
-
Artigos de Periódicos (40305)Ciências Exatas e da Terra (6158)
Este item está licenciado na Creative Commons License