dc.description.abstractA principal falha na cimentação adesiva de pinos de fibra de vidro é o deslocamento do conjunto pino/cimento resinoso. Supõe-se que, o desfavorável fator C no interior do canal, a alta tensão de contração sofrida pelo cimento resinoso sejam um dos fatores que diminuem de resistência de união obtidos entre a dentina e os sistemas adesivos. Este estudo avaliou a resistência ao deslocamento de pinos de fibra de vidro cimentados com cimentos resinosos associados ou não a diferentes tipos de sistemas adesivos dentro de canais radiculares.Os canais radiculares de 40 raízes bovinas foram instrumentados e preparados para receber pinos de fibra de vidro. Estas raízes foram , aleatoriamente separadas em 4 grupos (n=40), de acordo com os seguintes tratamentos: Scotchbond Multiuso Plus (ativador+primer+catalisador) + RelyX ARC (Gapc); Scotchbond Multiuso Plus (primer+adesivo) + RelyX ARC (Gpa); RelyX ARC sem aplicação de sistema adesivo (G0), Single Bond + RelyX ARC (Gsb). Após 48h, as raízes foram cortadas em 8 secções transversais (0,7vmm) até 5 mm aquém do ápice, e submetidas ao ensaio de ―push-out", em máquina de ensaio universal EMIC (1mm/min). Os resultados foram submetidos ao teste de ANOVA de uma via. Os resultados deste estudo mostraram que o uso de sistemas adesivos não aumentou a resistência ao deslocamento de pinos de fibra de vidro cimentados com cimentos resinosos.pt_BR
dc.description.abstractMost clinical failures involving fiber posts occur over time through debonding. It is assumed that, due to the unfavorable factor in the C canal, the high contraction stress experienced by the cement exceeds the values of bond strength obtained between dentin and adhesive systems. This study evaluated the resistance to displacement of glass fiber posts cemented with resin cement associated or not with different types of adhesive systems. Root canals of 40 bovine teeth were instrumented and prepared to receive fiberglass posts. The roots were randomly separated into four groups (n = 10), according to the following treatments: Scotchbond Multipurpose Plus (activator - primer - catalyst) RelyX ARC (Gapc); Scotchbond Multipurpose Plus (primer - bond) RelyX ARC (Gpa); RelyX ARC without adhesive system (G0); Single Bond RelyX ARC (Gsb). After 48 hours the roots were cut into eight transverse sections (0,7 mm), and tested as "push-out" in a universal testing machine EMIC (1mm/min). The results were analyzed by the test one-way ANOVA. The results of the present study are that the use of adhesive systems does not increase the displacement resistance of glass fiber posts cemented with resin cements.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectCimentospt_BR
dc.subjectGlass fiber posten
dc.subjectMateriais odontologicos : Adesivospt_BR
dc.subjectBond strengthen
dc.subjectPush-out testen
dc.subjectMateriais odontologicos : Avaliacaopt_BR
dc.subjectResin cementen
dc.subjectPinos dentáriospt_BR
dc.titleAvaliação da resistência ao deslocamento de pinos intra-radiculares de fibra de vidro : influência dos sistemas adesivospt_BR
dc.typeTrabalho de conclusão de graduaçãopt_BR
dc.contributor.advisor-coJardim, Patrícia dos Santospt_BR
dc.identifier.nrb000815693pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Odontologiapt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2011pt_BR
dc.degree.graduationOdontologiapt_BR
dc.degree.levelgraduaçãopt_BR


Files in this item

Thumbnail
   

This item is licensed under a Creative Commons License

Show simple item record