Mostrar registro simples

dc.contributor.authorTomazi, Michelypt_BR
dc.contributor.authorBayer, Cimeliopt_BR
dc.contributor.authorConceição, Paulo Césarpt_BR
dc.date.accessioned2013-11-28T01:47:22Zpt_BR
dc.date.issued2011pt_BR
dc.identifier.issn0100-0683pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/81600pt_BR
dc.description.abstractO fracionamento físico densimétrico é uma importante ferramenta no estudo da proteção física da matéria orgânica (MO) em agregados de solo, porém seus resultados podem ser alterados pela malha da peneira utilizada no preparo da amostra. A hipótese do presente estudo é de que a desagregação excessiva do solo pelo uso de peneira de 2 mm libera MO originalmente protegida dentro de agregados e, portanto, subestima o teor de C na fração leve-oclusa (C-FLO) e a magnitude da proteção física da MO intra-agregados, em comparação à peneira de 9,5 mm. Amostras (0–5 cm) de cinco solos foram coletadas em experimentos de longa duração (9–18 anos) nas regiões Centro-Oeste (quatro solos) e Sul do Brasil (um solo), sob sistemas de manejo convencional e conservacionista. Tomando as amostras ≤ 9,5 mm como referência, verificou-se subestimação de 2,9 a 15,7 % no C-FLO quando utilizadas amostras ≤ 2,0 mm, a qual foi mais expressiva nos sistemas conservacionistas de manejo de solo e positivamente correlacionada com os teores de C no solo (r = 0,92, p < 0,04), massa de macroagregados > 2 mm (r = 0,90, p < 0,02) e índice de estabilidade de agregados (r = 0,94, p < 0,01). Em três dos cinco solos estudados, o uso de amostras ≤ 2,0 mm levou à conclusão errônea de que os sistemas conservacionistas de manejo do solo não são efetivos na proteção física da MO do solo. Em estudos da proteção física da MO intra-agregados indica-se o uso da peneira de malha de 9,5 mm no preparo da amostra ou, alternativamente, da mesma malha da peneira empregada na preparação de amostras para avaliação da estabilidade de agregados, usualmente 8 mm ou maior.pt_BR
dc.description.abstractDensity fractionation is an important tool to determine the physical protection of organic matter within soil aggregates, but results may be affected by the mesh size used to sieve soil samples. The hypothesis of this study is that in comparison to 9.5 mm sieve, sieving through 2 mm mesh results in excessive soil disaggregation by releasing organic matter originally protected within aggregates and consequently leads to underestimations of the carbon content in the occluded light fraction (OLF-C) and of the magnitude of physical protection of organic matter within soil aggregates. Soil samples (0-5 cm) of five Brazilian soils under long-term experiments (9-18 yrs) were collected in the regions Center West (4 soils) and South (1 soil), under conventional and conservation soil management systems. Based on ≤ 9.5 mm soil samples as reference, an underestimation of 2.9–15.7% of the OLF-C pool was observed in comparison to ≤ 2.0 soil samples mm. This effect was more pronounced for conservation soil management systems and positively correlated with soil organic C content (r = 0.92, p < 0.04), macroaggregate mass > 2 mm (r = 0.90, p < 0.02) and aggregate stability index (r = 0.94, p < 0.01). In three of the evaluated soils, the use of ≤ 2.0 mm soil samples led to the erroneous conclusion that conservation soil management systems are not efficient to stabilize organic matter within soil aggregates. Therefore, a mesh size of 9.5 mm is indicated to evaluate the physical protection of organic matter in aggregates, or alternatively, the sieves used to prepare soil samples for aggregate stability analysis, i.e., usually greater than 8 mm.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.relation.ispartofRevista brasileira de ciência do solo. Campinas. Vol. 35, n.4 (jul./ago. 2011), p. 1323-1329pt_BR
dc.rightsOpen Accessen
dc.subjectQuímica do solopt_BR
dc.subjectPhysical fractionationen
dc.subjectConservation management systemen
dc.subjectMatéria orgânicapt_BR
dc.subjectLight occludeden
dc.titleO uso de amostras peneiradas a dois milímetros subestima a proteção física da matéria orgânica no solopt_BR
dc.title.alternativePhysical protection of soil organic matter is underestimated in two millimeter-sieved soil en
dc.typeArtigo de periódicopt_BR
dc.identifier.nrb000795113pt_BR
dc.type.originNacionalpt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples