Mostrar registro simples

dc.contributor.advisorDalcin, Paulo de Tarso Rothpt_BR
dc.contributor.authorZiegler, Brunapt_BR
dc.date.accessioned2012-07-19T01:30:53Zpt_BR
dc.date.issued2011pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/52963pt_BR
dc.description.abstractObjetivos: Avaliar a percepção da dispneia em pacientes com fibrose cística (FC) comparando com indivíduos normais, durante teste com cargas resistivas inspiratórias e durante teste de caminhada de seis minutos (TC6M). Secundariamente, avaliar a correlação entre os escores de dispneia induzida pelas cargas resistivas e os escores de dispneia provocada pelo TC6M. Métodos: estudo transversal em pacientes com FC (≥15 anos) e indivíduos normais. Os voluntários foram submetidos a teste com cargas resistivas inspiratórias, medida das pressões respiratórias máximas, espirometria, avaliação nutricional e TC6M. Resultados: Foram incluídos no estudo 31 pacientes com FC pareados com 31 indivíduos normais. À medida que a magnitude das cargas resistivas inspiratórias aumentou, os escores de dispneia aumentaram (p<0,001), porém não houve diferença entre grupos quanto ao escore de dispneia (p=0,654) e não houve efeito de interação (p=0,654). SpO2 foi menor em pacientes com FC (p<0,001) e aumentou à medida que a magnitude das cargas aumentou (p<0,001), sem ocorrer efeito de interação (p=,364). Vinte e seis (84%) indivíduos normais completaram o teste com cargas resistivas, comparado com apenas 12 (39%) dos pacientes com FC (p<0,001). Os escores de dispneia foram maiores ao final do TC6M do que no repouso (p<0,001), mas não houve diferença entre os grupos (p=0,080) e não houve efeito de interação (p=0,091). SpO2 foi menor nos pacientes com FC (p<0,001) e diminuiu do repouso ao final do TC6M nos pacientes com FC (p<0,001) com efeito de interação (p=0,004). Os escores de dispneia ao final do TC6M correlacionaram-se significativamente com os escores de dispneia induzidos pelo teste com cargas resistivas. Conclusão: a percepção da dispneia em pacientes com FC induzidos por teste com cargas resistivas inspiratórias e pelo TC6M não diferiu dos indivíduos normais. Contudo, os pacientes com FC descontinuaram o teste com cargas resistivas inspiratórias mais frequentemente. Além disso, houve correlação significativa entre o escore de percepção da dispneia induzida pelas cargas resistivas inspiratórias e pelo TC6M.pt
dc.description.abstractObjectives: To evaluate dyspnea perception in cystic fibrosis (CF) patients compared with normal subjects, during inspiratory resistive loading and the six-minute walk test (6MWT). Secondarily, to assess the correlation between dyspnea scores induced by resistive loads and those induced by the 6MWT. Methods: cross-sectional study in patients with CF (≥15 years old) and normal subjects. Volunteers underwent inspiratory resistive loading, measurement of maximal respiratory pressures, spirometry, nutritional evaluation, and the 6MWT. Results: Thirty-one CF patients and 31 paired normal subjects were included in the study. As the magnitude of the inspiratory loads increased, dyspnea scores increased (p<.001), but there was no difference between groups in dyspnea score (p=.654) and no group interaction effect (p=.654). SpO2 was lower in CF patients (p<.001) and increased as the magnitude of the loads increased (p<.001), with no interaction effect (p=.364). Twenty-six (84%) normal subjects completed the whole test, compared to only 12 (39%) CF patients (p<.001). Dyspnea scores were higher post-6MWT than at rest (p<.001), but did not differ between groups (p=.080) with no interaction effect (p=.091). SpO2 was lower in CF patients (p<.001) and decreased from resting to post-6MWT in CF patients (p<.001) with an interaction effect (p=.004). Post-6MWT dyspnea scores were significantly correlated with dyspnea scores induced by resistive loads. Conclusion: dyspnea perception in CF patients induced by inspiratory resistive loading and by 6MWT did not differ from normal subjects. However, CF patients discontinued inspiratory resistive loading more frequently. In addition, there were significant correlations between dyspnea perception score induced by inspiratory resistance loading and by the 6MWT.en
dc.format.mimetypeapplication/pdfpt_BR
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectCystic fibrosisen
dc.subjectFibrose císticapt_BR
dc.subjectDyspnea perceptionen
dc.subjectDispneiapt_BR
dc.subjectPulmonary function testsen
dc.subjectTeste de esforçopt_BR
dc.subjectTestes respiratóriospt_BR
dc.subjectInspiratory resistive load testingen
dc.subjectSix-minute walk testen
dc.titlePercepção da dispneia em pacientes com fibrose císticapt_BR
dc.title.alternativeDyspnea perception in cystic fibrosis patients en
dc.typeTesept_BR
dc.identifier.nrb000836099pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Medicinapt_BR
dc.degree.programPrograma de Pós-Graduação em Ciências Pneumológicaspt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.date2011pt_BR
dc.degree.leveldoutoradopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples