Mostrar registro simples

dc.contributor.advisorConceição, Andréa de Azevedo Britopt_BR
dc.contributor.authorSiqueira, Karina Gomes dept_BR
dc.date.accessioned2011-09-28T01:17:41Zpt_BR
dc.date.issued2010pt_BR
dc.identifier.urihttp://hdl.handle.net/10183/32139pt_BR
dc.description.abstractA técnica do pino anatômico vem sendo bastante difundida para reforçar raizes fragilizadas em restaurações de grande porte. O reembasamento do pino de fibra de vidro com resina composta permite um melhor preenchimento do canal, evitando grandes espessuras de cimento. O presente estudo avaliou a fenda de contração de polimerização de dois tipos de resinas compostas: uma convencional a base de metacrilato (Filtek Z350 XT/3M ESPE) e uma de baixa contração a base de silorano (Filtek P90/3M ESPE), utilizadas para revestir pinos de fibra de vidro WhitePostDC/FGM. Foram confeccionados 12 corpos de prova para cada grupo. O pino de fibra de vidro foi preparado com silano e adesivo e, após, foi inserido em uma perfuração posicionada no centro de uma matriz metálica de 6 mm de diâmetro interno e 6 mm de altura, a qual foi posteriormente preenchida pela resina composta. Logo após, a superfície da resina foi recoberta com uma matriz de poliéster e pressionada com uma placa de vidro para a remoção dos excessos de resina. A seguir, essa foi fotopolimerizada por 40 segundos através do aparelho fotopolimerizador tipo LED SmartLite PS (Dentsply), com densidade de 950 mW/cm². As amostras foram armazenadas em estufa biológica por 24 horas. Após esse tempo, a superfície pino/resina foi levada a uma politriz para o seu polimento superficial. Posteriormente, os corpos de prova foram metalizados para a análise da fenda de contração de polimerização em um microscópio eletrônico de varredura (JSM 5800). As medições foram feitas em 4 pontos para cada corpo de prova, na interface da matriz metálica e a resina composta, em áreas correspondentes a 3, 6, 9 e 12 horas. O cálculo da média aritmética dos valores das fendas observadas no MEV, foi de 7,55 (± 2,84) μm para o grupo Filtek Z350 XT (3M ESPE) e de 0,66 (± 1,33) μm para a Resina Filtek P-90 (3M ESPE) . Os valores foram analisados pelo teste estatístico de U Mann-Whitney, com nível de significância de 5%, mostrando que houve diferença estatisticamente significativa entre os grupos, sendo que os pinos anatômicos confeccionados com a resina P90 apresentaram as menores fendas de contração.pt_BR
dc.description.abstractThis study evaluated the polymerization shrinkage gap of anatomic posts made with two types of composites: a conventional methacrylate based (Filtek Z 350XT - 3M ESPE) and a low-shrinkage Silorane based (Filtek P90-3M ESPE ). The fiber glass post was inserted in the center of a metal matrix of 6 mm internal diameter and 6 mm high, which was subsequently filled with resin. The post was centered with the aid of a guide with a diameter equal to the matrix. After a plate of glass was pressed on the surface of the resin for removal of excess, with subsequent photopolymerization for 40 seconds with LED curing unit type FreeLight Elipar (3M ESPE). After the surface of the resin/post was polished in a polishing machine. The samples were metallized and taken for analysis of polymerization shrinkage gap in a scanning electron microscope (JSM-5800). Measurements were made at 4 points for each specimen at the interface of matrix and composite and the composite resin and fiber post, in areas corresponding to 3, 6, 9 and 12 hours. The results were tested using the U Mann- Whitney , with the significance level of 5% and showed the following average values for each group: Z350 (7,55 μm) and P90 (0,66 μm), demonstrating statistically significant differences in relation to the gap of contraction. Based on these results, we concluded that the resin composite Filtek P90 showed the lowest polymerization shrinkage when compared to resin Filtek Z350.en
dc.format.mimetypeapplication/pdf
dc.language.isoporpt_BR
dc.rightsOpen Accessen
dc.subjectAnatomic posten
dc.subjectPinos dentáriospt_BR
dc.subjectResinas compostaspt_BR
dc.subjectComposite methacrylate baseden
dc.subjectComposite silorane baseden
dc.subjectMateriais odontologicos : Avaliacaopt_BR
dc.subjectPolymerization shrinkageen
dc.titleAvaliação da fenda de contração de polimerização de dois tipos de resinas compostas utilizadas na confecção de pinos anatômicospt_BR
dc.typeTrabalho de conclusão de graduaçãopt_BR
dc.identifier.nrb000785687pt_BR
dc.degree.grantorUniversidade Federal do Rio Grande do Sulpt_BR
dc.degree.departmentFaculdade de Odontologiapt_BR
dc.degree.localPorto Alegre, BR-RSpt_BR
dc.degree.graduationOdontologiapt_BR
dc.degree.levelgraduaçãopt_BR


Thumbnail
   

Este item está licenciado na Creative Commons License

Mostrar registro simples