Moldagens funcionais em prótese total : estudo comparativo de quatro materiais e de duas técnicas, simples e dupla
| dc.contributor.author | Marchezan, Walter | pt_BR |
| dc.contributor.author | Feltrin, Pedro Paulo | pt_BR |
| dc.contributor.author | Zanetti, Raquel Virgínia | pt_BR |
| dc.contributor.author | Zanetti, Artemio Luiz | pt_BR |
| dc.date.accessioned | 2025-09-24T06:55:33Z | pt_BR |
| dc.date.issued | 2005 | pt_BR |
| dc.identifier.issn | 0103-6971 | pt_BR |
| dc.identifier.uri | http://hdl.handle.net/10183/297161 | pt_BR |
| dc.description.abstract | Este trabalho avaliou comparativamente, em laboratório, a fidelidade dimensional de quatro materiais de moldagem usados nas moldagens finais em prótese total, um hidrocolóide irreversível (Hidrogum), wn poliéter (lmpregum) e dois silicones de adição (Honigum e Extrude), bem como a técnica de dupla moldagem, com ou sem alívio, usando o material Extrude de consistências média e leve. Concluiu-se que, com exceção do material Extrude em moldagem simples, os silicones e o poliéter tiveram desempenho semelhante, e que o hidrocolóide irreversível evidenciou os piores resultados. Outra conclusão foi que as duas técnicas de dupla moldagem usando materiais de consistências diferentes mostraram resultados semelhantes ao Honigum e Impregum, sendo mais precisas que estes na reprodução da altura, medida relacionada com a moldagem da zona de postdamming no paciente edêntulo. | pt_BR |
| dc.description.abstract | This work has evaluated comparatively, in laboratory, four impression materials' dimensional fidelity, used in dentures final impressions. These are an irreversible hydrocolloid (Hidrogum), a polyether (lmpregum), and two addition silicones (Honigum and Extrude ). The work evaluated as well the double impression technique, with or without relief, using the medium and light consistency Extrude material. The conclusion is that, except from the Extrude material in a monophasis impression, the addition silicones and the polyether had an similar performance, and that the irreversible hydrocolloid has given the worst results. Another conclusion was that the two double impression techniques, when using different consistency materials, have given similar results to the Honigum and lmpregum, being more precise than those to reproduce height, measure related to impression of post-daming in edentulous patients | en |
| dc.format.mimetype | application/pdf | pt_BR |
| dc.language.iso | por | pt_BR |
| dc.relation.ispartof | RGO. Porto Alegre. Vol. 53, n.1 (jan./mar. 2005), p. 12-16 | pt_BR |
| dc.rights | Open Access | en |
| dc.subject | Dentures | en |
| dc.subject | Prótese total | pt_BR |
| dc.subject | Impression materiais | en |
| dc.subject | Materiais para moldagem odontológica | pt_BR |
| dc.title | Moldagens funcionais em prótese total : estudo comparativo de quatro materiais e de duas técnicas, simples e dupla | pt_BR |
| dc.title.alternative | Comparative study of techniques for functional moldings in prosthesis | en |
| dc.type | Artigo de periódico | pt_BR |
| dc.identifier.nrb | 000455220 | pt_BR |
| dc.type.origin | Nacional | pt_BR |
Files in this item
This item is licensed under a Creative Commons License
-
Journal Articles (44377)Health Sciences (12174)