Comparação da sobrevida entre indivíduos submetidos à cirurgia para substituição valvar aórtica utilizando próteses mecânicas ou biológicas em uma coorte brasileira
dc.contributor.advisor | Wender, Orlando Carlos Belmonte | pt_BR |
dc.contributor.author | Almeida, Adriana Silveira de | pt_BR |
dc.date.accessioned | 2011-04-26T05:59:59Z | pt_BR |
dc.date.issued | 2010 | pt_BR |
dc.identifier.uri | http://hdl.handle.net/10183/28695 | pt_BR |
dc.description.abstract | Este estudo avalia mortalidade, eventos hemorrágicos e reoperação em pacientes submetidos à cirurgia para troca valvar aórtica utilizando substituto biológico ou mecânico, com poder de relevância na seleção do tipo da prótese. Foram selecionados, randomicamente, 301 pacientes submetidos à cirurgia para troca valvar aórtica entre 1990 e 2005, com seguimento máximo de 20 anos. A sobrevivência em 5, 10 e 15 anos após cirurgia utilizando substituto mecânico foi de 83,9%, 75,4% e 60,2% e, para substituto biológico, foi de 89,3%, 70,4% e 58,4%, respectivamente (p=0,939). Os fatores associados com o óbito foram: idade, obesidade, doença pulmonar, arritmias, eventos hemorrágicos e insuficiência valvar aórtica. A probabilidade livre de reoperação desses pacientes em 5, 10 e 15 anos após cirurgia utilizando substituto mecânico foi de 97,9%, 95,8% e 95,8% e, para bioprótese, foi de 94,6%, 91,0% e 83,3%, respectivamente (p=0,057). Os fatores associados com reoperação foram: insuficiência renal, endocardite de prótese e idade. A probabilidade livre de eventos hemorrágicos em 5, 10 e 15 anos após cirurgia utilizando substituto mecânico foi de 94,5%, 91,7% e 91,7% e, para bioprótese, foi de 98,6%, 97,8% e 97,8%, respectivamente (p=0,047). Os fatores associados com eventos hemorrágicos foram: insuficiência renal e prótese mecânica. Os autores concluíram que: 1) a mortalidade foi estatisticamente semelhante entre os grupos; 2) as características basais dos pacientes foram os maiores determinantes de mortalidade tardia após a cirurgia; 3) houve uma tendência à reoperação para o grupo com bioprótese; 4) pacientes com prótese mecânica tiveram mais eventos hemorrágicos ao longo do tempo; 5) os dados encontrados no presente estudo são concordantes com a literatura atual. | pt_BR |
dc.description.abstract | This paper evaluates mortality, bleeding events and reoperation in patients subjected to surgery for replacement of the aortic valve using a biological or a mechanical substitute, where selection of the type of prosthesis is relevant. Three hundred and one patients who had been subjected to aortic valve replacement surgery between 1990 and 2005, with a maximum follow-up period of 20 years, have been randomly selected. Survival at 5, 10 and 15 years after surgery using a mechanical substitute was 83.9%, 75.4% and 60.2% and, for a biological substitute, was 89.3%, 70.4% and 58.4%, respectively (p=0.939). Factors associated with death were: age, obesity, pulmonary disease, arrhythmia, bleeding and aortic valve failure. The probability free of reoperation for these patients at 5, 10 and 15 years after surgery using a mechanical substitute was 97.9%, 95.8% and 95.8% and, for those using bioprostheses, was 94.6%, 91.0% and 83.3%, respectively (p=0.057). Factors associated with reoperation were: renal failure, prosthesis endocarditis and age. The probability free of bleeding events at 5, 10 and 15 years after surgery using the mechanical substitute was 94.5%, 91.7% and 91.7% and, for bioprostheses, was 98.6%, 97.8% and 97.8%, respectively (p=0.047). Factors associated with bleeding events were: renal failure and mechanical prostheses. The authors have concluded that: 1) mortality was statistically similar in the groups; 2) patient characteristics at baseline were a major determinant of late mortality after surgery; 3) there was a tendency toward reoperation in the bioprostheses group; 4) patients using a mechanical prosthesis had more bleeding events as time passed; 5) the data presented in this paper is in accordance with current literature. | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | por | pt_BR |
dc.rights | Open Access | en |
dc.subject | Aortic valve replacement | en |
dc.subject | Valva aórtica | pt_BR |
dc.subject | Implante de prótese de valva cardíaca | pt_BR |
dc.subject | Aortic prostheses | en |
dc.subject | Aortic valve surgery | en |
dc.subject | Bioprótese | pt_BR |
dc.subject | Próteses e implantes | pt_BR |
dc.subject | Bioprostheses | en |
dc.subject | Mechanical prostheses | en |
dc.subject | Predictors | en |
dc.title | Comparação da sobrevida entre indivíduos submetidos à cirurgia para substituição valvar aórtica utilizando próteses mecânicas ou biológicas em uma coorte brasileira | pt_BR |
dc.type | Dissertação | pt_BR |
dc.contributor.advisor-co | Picon, Paulo Dornelles | pt_BR |
dc.identifier.nrb | 000771321 | pt_BR |
dc.degree.grantor | Universidade Federal do Rio Grande do Sul | pt_BR |
dc.degree.department | Faculdade de Medicina | pt_BR |
dc.degree.program | Programa de Pós-Graduação em Ciências da Saúde: Cardiologia e Ciências Cardiovasculares | pt_BR |
dc.degree.local | Porto Alegre, BR-RS | pt_BR |
dc.degree.date | 2010 | pt_BR |
dc.degree.level | mestrado | pt_BR |
Este item está licenciado na Creative Commons License
-
Ciências da Saúde (8799)