Thermal behavior and range distribution of 209bi implanted the into ai/v bilayer structure
View/ Open
Date
1988Author
Type
Subject
Abstract
350-keV 209Bi + was implanted into an A1 (1000 Å)/V bilayer system. The Bi depth distribution measured by Rutherford backscattering agrees well with predictions obtained via the Monte-Carlo simulation method (TRIM code). Diffusion coefficients for Bi in both the V substrate of the AI/V system and the pure V foil are extracted after thermal annealings in a temperature range between 200 and 700 °c. The results show that the Ri ions follow a hindered diffusion at the Al film of the AI/V bilayer an ...
350-keV 209Bi + was implanted into an A1 (1000 Å)/V bilayer system. The Bi depth distribution measured by Rutherford backscattering agrees well with predictions obtained via the Monte-Carlo simulation method (TRIM code). Diffusion coefficients for Bi in both the V substrate of the AI/V system and the pure V foil are extracted after thermal annealings in a temperature range between 200 and 700 °c. The results show that the Ri ions follow a hindered diffusion at the Al film of the AI/V bilayer and for temperatures higher than 580 °C diffuse regularly in the V bulk. ...
In
Journal of applied physics. Woodbury. Vol. 63, no. 9 (May 1988), p. 4431-4434
Source
Foreign
Collections
-
Journal Articles (40281)Engineering (2437)
-
Journal Articles (40281)Exact and Earth Sciences (6158)
This item is licensed under a Creative Commons License